9) EXCHANGE OF PRESSER FOOT
Check the OFF-status condition of a power switch before exchanging the presser foot.
Warning
① Remove the needle in the needle holder.
② Remove the rubber capⓐ. (Refer to the Figure 63)
③ Loosen the presser bar adjusting screwⓑ and the presser bar
connection bracket clamp screwⓒ (Refer to the Figure 63)
④ Loosen the knife holder guide clamp screwⓓ. (Refer to the
Figure 64)
⑤ Loosen the knife holder shaft support bar clamp screwⓔ and
remove the knife holder shaft support bar A.
(Refer to the Figure 65)
38
ⓑ
ⓐ
ⓝ
ⓒ
ⓚ
A
[ Figure 63 ]
ⓓ
[ Figure 64 ]
ⓗ
ⓕ
ⓔ
[ Figure 65 ]