(2) Air-compressed device (optional) installation
[ Figure 17 ]
① Connect the air hoseⓐ to the manifolder block of the filter regulator and solenoid valve.
② Connect the air hoseⓑ to the upper fitting of the air-compressed cylinder and the left side of the solenoid valve A.
③ Connect the air hoseⓒ to the lower fitting of the air-compressed cylinder and the right side of the solenoid valve A.
④ Connect the air hoseⓓ to the suction pipe and the solenoid valve B.
⑤ Connect the air hoseⓔ to the cutter cylinder and the solenoid valve C.
⑥ Connect the cableⓕ which is written in 'PF' linking to the control box to the solenoid valve A.
⑦ Connect the cableⓖ which is written in 'CL' linking to the control box to the solenoid valve B.
⑧ Connect the cableⓗ which is written in 'TT' linking to the control box to the solenoid valve C.
⑨ After installing to the table, open the air-compressed regulatorⓘ of the filter regulator and set the compressed air at the
0.4~0.5 bar.