conditioning and cooling systems. Mixed
refrigerants have to be disposed of
according to the current regulations.
Never use ACX equipment with systems
containing compressed air; mixtures of
R134a or R1234yf with air or oxygen may
be potentially flammable.
Do not modify calibration of safety
devices. Do not remove seals of safety
valves and of control systems. Do not use
external tanks or other storage containers
that are not type-approved or without
safety valves.
Make sure the equipment's aeration and
ventilation ports are not obstructed or
covered while the equipment is operating.
HOSE
CONNECTIONS:
contain pressurised refrigerant. Before
changing the service couplers, check the
respective
pressures
(pressure gauge). Before connection to a
car
A/C
system,
tank/cylinder,
check
couplers are closed (unscrewed HP and
LP
valves).
Scrupulously
instructions on the equipment's display.
QUICK COUPLERS
CLOSING/OPENING:
Hoses
may
in
the
hoses
to
an
external
that
the
quick
follow
Opening (connect to
the vehicle):
clockwise
Closing (detach from
the vehicle):
counter clockwise
EN | 6 | ACX120/220 | Safety conditions
MAINTENANCE/GENERAL CLEANING:
The equipment has to be serviced at the
intervals indicated by the equipment itself.
The service station maintenance has to
be
performed
procedures described in this manual and
to the current safety regulations.
Use only MAHLE original parts.
When the equipment requires the drier
filter and the vacuum pump oil to be
changed, you have to be careful in the
replacement.
A/C service station maintenance can be
carried out exclusively by a trained
operator or by a service man of a MAHLE
certified seller.
Do not use chemical agents for the
service station cleaning as they could
attack the material or the surface.
STOP FOR LONG PERIOD: Store the
equipment in a safe place, disconnected
from the mains, away from excessive
temperatures, humidity and the risk of
damaging impact.
Contact the Technical Service to run a
the
safety shutdown of the equipment, and if
scrapping the unit, to drain and recycle
the R134a or R1234yf refrigerant as
required by local legislation.
To
resume
installation (there is no need to register
the unit anew on the website) and run the
commissioning
operational checks as required by local
legislation.
according
to
operation,
repeat
trials
and
the
the
regular