Machine Specific Safety Practices
All aspects of the machine have been designed with safety in mind. Rotating parts are not
always shielded by machine components or by the work piece. Do not force the machine.
PERSONAL PROTECTIVE EQUIPMENT
Eye and hearing protection must be worn while
using the machine. These safety items do not
impose constraints to the safe operation of the
machine.
OPERATING CONDITIONS
Do not operate the machine if it is not mounted to
the work piece as described in this manual.
TOOLING
The machine is provided with all the tools for the
setup and operation of the machine. Remove all
adjustment tools before starting the machine.
LIFTING
Most of the machine components are heavy and
must be moved or lifted with approved rigging and
practices. Climax accepts no responsibility for the
selection of lifting equipment. Always follow your
plant's procedures for lifting heavy objects. Do not
lift heavy objects by yourself as serious injury can
result.
CUTTING TOOLS AND FLUIDS
There are no cutting or cooling fluids supplied with
this machine. Keep cutting tools sharp and clean.
CONTROLS
The machine controls are designed to withstand
the rigors of normal use and external factors. The
on-off switches are clearly visible and identifiable.
If hydraulic power supply failure occurs, be sure to
turn off the supply before leaving the machine.
DANGER ZONE
The operator and other persons can be anywhere
in the vicinity of the machine. The operator must
ensure there are no other persons in danger from
the machine.
METAL FRAGMENT HAZARD
The machine produces metallic fragments during
normal operation. You should wear eye protection
at all times when working with the machine. Only
P/N 66188, Rev. 5
remove fragments with a brush after the machine
has stopped completely.
RADIATION HAZARDS
There are no systems or components on this
machine that are capable of producing hazardous
EMC, UV or other radiation hazards. The machine
does not use lasers nor does it create hazardous
materials such as gasses or dust.
ADJUSTMENTS AND MAINTENANCE
All adjustments, lubrication and maintenance
should be done with the machine stopped, and
locked out from all power sources. The shut-off
valves should be locked and tagged out before
performing any maintenance. Do not operate the
machine if moving parts are misaligned, binding or
broken. If the machine or parts are damaged, have
the machine repaired before use.
WARNING LABELS
Warning labels are already attached to your
machine.
Contact
Climax
replacements are required.
MAINTENANCE
Be sure the machine components are free of debris
and properly lubricated prior to use. Have your
machine serviced by a qualified repair person using
only identical replacement parts.
NOISE LEVEL
85 dB(A) or higher – Hearing Protection is required.
STORED ENERGY
Hydraulic fluids could still be under pressure! Make
sure the HPU is shut off and locked out properly.
MSDS
Material Data Safety Sheets are included in the
maintenance manual.
UNINTENTIONAL STARTING
Prevent unintentional starting. The machine must
be properly locked out and/or shut down before
maintenance.
immediately
if
Page 3
Need help?
Do you have a question about the LM5200 and is the answer not in the manual?