Imaging Unit Motors
The Imaging Unit Motors (CMYK) are all mounted to single mounting plate by 2 (metal, 6 mm) screws. In addition to
the screws, each motor has a corresponding connection to the Motor Driver Board. Use the following procedure to
remove one or all four Imaging Unit Motors.
Note:
The Black Imaging Unit Motor is oriented differently than the other colors.
1.
Remove the
Card Cage.
2.
Remove 2 (metal, 6 mm) screws that secure the motor.
3.
Disconnect the motor's connector on the Motor Driver Board.
Fuser Motor
The Fuser Motor is mounted to the frame with 2 (metal, 6 mm) screws, and connects to the Motor Driver Board.
1.
Remove the
Card Cage.
2.
Remove 2 (metal, 6 mm) screws that secure the motor.
3.
Release the Fuser Motor wiring from the 3 clamps.
4.
Disconnect the motor's connector on the Motor Driver Board.