Appendix B Flow Data
High Efficiency Twin 1.5 Water Softeners—Flow Rate Data (gpm)
Model
Minimum Continuous
HE-060
2.1
HE-090
2.8
HE-120
2.8
HE-150
5
HE-210
11.5
*The Suggested Progressive Flow Trip Point is simply a suggested flow rate at which point an additional tank will be
brought on line if facility flow demand meets this rate. The Culligan Controller will not remove a tank brought on line by at-
taining the Trip Point unless the flow is <95% of the Trip Point amount for a 60-second period. In the event additional units
are not brought on line or off line when desired, simply adjust the programmed Trip Point. Refer to the system instruction
manual, Operation and Programming sections for more information about the Progressive Flow mode of operation.
Culligan® High Efficiency 1.5 Twin Water Softener
66
Table 14.
High Efficiency 1.5 Twin flow rate data.
Service
Peak
25.1
31.5
26.6
35.2
23.3
31.8
27.2
35.8
28.0
37.4
*Suggested
Progressive
Back-
Flow Trip
wash
Point
18.8
5.5
20.0
5.5
17.5
5.5
20.4
7.1
21
11.5
Drain
Brine
Slow
Fast
Draw
Rinse
Rinse
0.93
0.73
5.5
1.52
1.43
5.5
1.48
1.19
5.5
1.5
1.28
7.1
1.9
1.6
11.5
Cat. No. 01024821
66