Installation - Culligan High Efficiency 1.5 Twin Series Installation, Operation And Service Instructions

Table of Contents

Advertisement

Installation

NOTE
Read this section carefully. Follow all local plumbing and electrical codes.
Each HE 1.5 Twin water softener contains the following item(s):
FRP water softening media tanks.
Control valves
Media—refer to the table below for quantities of: Cullex Resin and Cullsan underbedding
Manifold kit(s)
Included with valve:
Meter
1½ NPT Plastic Adapter
Softener Kit
Drain line flow controls
Brine connection coupling, tube fitting
Drain line fitting and clamp
Extra eductors
Twin Small Parts Kit
Optional Brine tank
Optional manual 1.5" bypass valve (P/N 01024216)
Locate Softener
1.
Select a space that is level and allows a sufficient amount of room above and behind the softener tank(s) for
service access and plumbing supply and drain lines. Allow a minimum of 24 inches (61 cm) above the top of the
system.
NOTE
Upon initial installation or in the event the distribution pipe ever needs to be replaced, as much as 75
inches (191 cm) of clearance may be required above the tank if it is not possible to SAFELY lie the tank
on its side for installation/replacement of this distributor.
2.
Floor surface—Choose an area with a smooth, solid and level floor capable of supporting the operating weight
of the softening system.
3.
Drain facilities—A nearby drain must be capable of handling the water softener discharge flow rates during the
backwash cycle of the regeneration process. Refer to the Specifications on
ing the backwash flow rate.
4.
Screw the control assembly onto the empty media tank until it seats. Mark the front of the tank, then remove the
control assembly.
Culligan® High Efficiency 1.5 Twin Water Softener
4
page 3
for information concern-
Cat. No. 01024821