Installing the Modem In the Remote
Open the remote monitor housing by removing the two screws and squeezing the sides of the monitor housing slightly.
Insert the modem board (P/N 01020747) into the socket on the back of the remote board (see Figure 41). Make sure that
all of the pins in all four connectors are aligned and make sure the modem is fully seated into all of the sockets. Snap the
two halves of the remote housing back together using light finger pressure and insert the two screws.
Refer to the GBE Programming for Commercial Softeners and Filters, except HF xN Manual (P/N 01027295) for pro-
gramming information. This manual can be obtained from your local dealer, on CPort (www.cport.culligan.com) under the
Technical Service Tab
or on the Service Tech App.
Flow Meter
See the
"Electrical Schematic" on page 26
Refer to the GBE Programming for Commercial Softeners and Filters, except HF xN Manual (P/N 01027295) for pro-
gramming information. This manual can be obtained from your local dealer, on CPort (www.cport.culligan.com) under the
Technical Service Tab
or on the Service Tech App.
Culligan® High Efficiency 1.5 Twin Water Softener
32
Figure 41.
Back of remote board.
for information regarding the flow meter connections.
Cat. No. 01024821
32