Culligan Soft-Minder 2005 Owner's Manual

Culligan Soft-Minder 2005 Owner's Manual

Twin water softener

Advertisement

Cat. No. 01017584
Rev. C 12/13/07
DCO # 010262
Owners Guide
& Installation
Instruction
Supplement
Soft-Minder
Twin
®
Water Softener
Models from 2005
© 2007 Culligan International Company

Advertisement

Table of Contents
loading

Summary of Contents for Culligan Soft-Minder 2005

  • Page 1 Cat. No. 01017584 Rev. C 12/13/07 DCO # 010262 Owners Guide & Installation Instruction Supplement Soft-Minder Twin ® Water Softener Models from 2005 © 2007 Culligan International Company...
  • Page 2 We promise that you’ll never want to be without it again. With Culligan’s many years of knowledge and experience in water treatment, you can be confident that the model you selected has been designed and engineered to provide years of service with a minimum of care and attention.
  • Page 3: Table Of Contents

    Service Check List ........21 Culligan 61 Soft-Minder Twin Performance Data Sheet ..22 Culligan 91 Soft-Minder Twin Performance Data Sheet .
  • Page 4: Specifications

    Measured from top of media to top surface of tank threads. (backwashed and drained). Measured from top of underbedding to top surface of tank threads. Backwash at 120 psi (830 kPa). 10 minute backwash, 3.3 lb 9” model, 5 lb (2.7kg) 10” model. Culligan Platinum Plus Series ® SM-61 Model...
  • Page 5: Introduction

    Softened water is not recommended for house plants because a build-up of sodium in the soil may interfere with efficient absorption of water by the plant root system. Additional information may be obtained from your independently operated Culligan dealer. Introduction...
  • Page 6 Some localities have corrosive water. A softener cannot correct this problem and so its printed warranty disclaims liability for corrosion of plumbing lines, fixtures or appliances. If you suspect corrosion, your Culligan Man has equipment to control the problem.
  • Page 7 Since a predetermined amount of salt is dissolved with each brine refill cycle, the salt must be periodically replenished in order to maintain efficient operation. Your Culligan service person will be able to tell you about how often salt must be added to the salt storage container.
  • Page 8: Preparation

    Pressure reducing valve (if pressure exceeds 125 psi [860 kPa], PN 00-4909-00 or equivalent) • Pipe and fittings suited to the type of installation • Water softener salt (rock, solar or pellet salt formulated specifically for water softeners) Culligan Soft-Minder Twin Softeners ® ion exchange resin, underbedding and outlet manifold. ®...
  • Page 9 Application Water quality - Verify that raw water hardness and iron are within limits. Note the hardness for setting the salt dosage and recharge frequency. Pressure - If pressure exceeds 125 psi (860 kPa), install a pressure reducing valve (see materials checklist). On private water systems, make sure the minimum pressure (the pressure at which the pump starts) is greater than 20 psi (140 kPa).
  • Page 10: Installation

    Tank size will determine which size flow control to install. Use the 2.00 gpm for the 9-inch tank and 10-inch tank. See table 2 for DLFC selections Install the DLFC by removing the drain line elbow adapter. Unscrew Culligan Soft-Minder Twin Softeners ® TO HOSE BIBS...
  • Page 11 the retainer, remove and replace with the proper size. Install the retainer and the drain line elbow adapter. The numbered side of the DLFC must face down. Start-Up Place approximately 1” of water above the grid plate (if used) in your salt tank. Salt may be placed in the unit at this time. Place softener in a bypass position.
  • Page 12 Set Down buttons to set the desired time of day for Regeneration to occur. Note: This does not display if Regeneration occurs immediately. Press the Extra Regeneration button. Culligan Soft-Minder Twin Softeners ® Figure 3 Timer Display Figure 4 Timer Display During Normal Operation...
  • Page 13 Set Regeneration Day Override. Use the Set Up or Set Down buttons to set the maximum number of days before a Regeneration cycle must occur. Press the Extra Regeneration button to exit the program. Note: Refer to the 9100 Control Service Manual and the SE Timer Supplemental Service Manual for additional information on programming and start-up procedures.
  • Page 14: Sanitizing Procedure

    Caution! Hazard from toxic fumes! Chlorine bleach and common iron control chemicals may generate toxic fumes when mixed. • If the unit uses culligan Sofner-Gard any other reducing agent, disconnect the device feeding the chemical(s) and manually regenerate the unit before sanitizing.
  • Page 15 Remove the brine tank cover. Pour directly into the brine chamber 1/3 - 1/2 cup of common household bleach (5.25% sodium hypochlorite) for each cubic foot of resin in the tank. Do not use lemon scented bleaches, or similar bleaches that contain perfumes. Manually start recharge.
  • Page 16: Salt Supply, Usage & Service

    “bridging”. Regardless of what type of salt is used, we recommend Culligan Brand Salt as suggested by your Culligan Dealer. He or she is the expert and can provide you with the best product for your Culligan Water Conditioner.
  • Page 17: Care & Cleaning

    “boil water” situation, the operation of the water softener should be discontinued until it is verified that the water is again potable. To do this, move lever on bypass valve to the “bypass” position. Then, call your Culligan dealer to have your system sanitized before it is placed back into service.
  • Page 18: When And How To Bypass Your Water Conditioner

    If lines to outside faucets do not bypass the water conditioner, and you do not want to waste soft water on lawn sprinkling or other outside uses. If you are going away on vacation and want to save salt by not having the unit recharge while you’re away. Culligan Soft-Minder Twin Softeners ®...
  • Page 19: Service Check List

    Guests, family additions, new water-using appliances, etc., all will result in more water usage and will require more capacity from your conditioner. You can reprogram your recharging schedule by following the directions on pages 9 and 10. Call your Culligan dealer for advice and save a service call.
  • Page 20: Performance Data Sheet

    Performance will vary based on local water conditions. The substances reduced by this system are not necessarily in your water. Culligan water softeners are designed to work with any salt of good quality, although it is recommended that you ask your local Culligan Man for his suggestion on the best type and grade of salt to use in this softener.
  • Page 21 Performance will vary based on local water conditions. The substances reduced by this system are not necessarily in your water. Culligan water softeners are designed to work with any salt of good quality, although it is recommended that you ask your local Culligan Man for his suggestion on the best type and grade of salt to use in this softener.
  • Page 22 Parts List Control Valve Culligan Soft-Minder Twin Softeners ®...
  • Page 23 Item No. Part No. Description 01017575 Control Valve Assembly 01017764 Valve Body 01017808 Screw 01017809 End Plate 01017810 End Plug 01009207 O-Ring 01012896 Piston - Top Assembly 01012897 Seal & Spacer Kit - Top 01012898 Seal & Spacer Kit - Bottom 01012895 Piston - Bottom Assembly Injector Assembly - 9”...
  • Page 24 Power Head Culligan Soft-Minder Twin Softeners ®...
  • Page 25 Item No. Part No. Description 01013002 01017766 Transformer w/ Power Cord 01013003 Drive Gear Assembly, Lower 01013004 Drive Gear Assembly 01009210 Geneva Wheel 00401865 Cover Screw 00402016 Retaining Ring 01013005 Ground Plate 01009225 Screw 01017805 Drive Motor, 24 Volts 00402011 Screw 00401871 Washer...
  • Page 26 Plastic tube assembly, 9100, up to 10” tanks 01017577 Plastic tube assembly, 9100, up to 14” tanks 01017765 Second tank adapter assembly, 9100 Meter Assembly Item No. Part No. Description 01017767 Turbine meter assembly 01017768 Meter Cable Culligan Soft-Minder Twin Softeners ® Qty. Qty.
  • Page 27: Bypass Valve

    Bypass Valve Item No. Part No. Description 01017769 1” Stainless Steel Bypass Valve NPT Timer Assembly Item No. Part No. Description 01017763 SE Timer Assembly Qty. Qty. Parts List...
  • Page 28 01017677 QH Tank Replacement, 10”, w/o Fillport, Empty 01017678 Top Strainer - Fine Slot 01009847 Top Strainer - Wide Slot 01011195 O-Ring, Manifold P1009099 Outlet Manifold - 9” 01016176 Outlet Manifold - 10” 01014539 Culligan Soft-Minder Twin Softeners ® Qty.
  • Page 29 16” and 18” Brine Systems Item Part Number Description 01-0187-05 Brine System, 250 lb 01-0187-15 Brine System, 375 lb 01-0187-09 Replacement Tank, 250 lb 01-0187-16 Replacement Tank, 375 lb 01-0187-04 Cover, 250 lb 01--0187-17 Cover, 375 lb 01-0187-07 Salt Plate, 250 lb 01-0187-13 Salt Plate, 375 lb 01-0187-07...
  • Page 30 Brine Valve Item Part Number Description 01-0187-06 Brine Valve 01-0187-10 BLFC Elbow - 0.45 gpm 01-0187-11 BLFC Elbow - 0.8 gpm Culligan Soft-Minder Twin Softeners ®...
  • Page 31: Records And Data

    Records and Data Important Data on Your Water Conditioner It is advisable to have the salesperson or installer fill in the information below for your future reference. If this has not been done, please ask for it, as it is necessary if you contact your dealer. Identification Model Name ___________________________________________________ Catalog No.
  • Page 32: Warranty

    (such as chlorine, ozone, chloramines and other related components), alteration, installation or operation contrary to our printed instructions, or by the use of accessories or components which do not meet Culligan specifications, is not covered by this warranty. Refer to the specifications section in the Installation and Operating manual for application parameters.
  • Page 33: Promise

    You Get Your Water Expert, The Culligan Man We’re here to provide you with fast, dependable service, making sure any problems you have are taken care of. The Culligan Man has been around for over seventy years, delivery dependable service all along. That’s why people say “Hey, Culligan Man! ”...

This manual is also suitable for:

Soft-minder sm-61Soft-minder sm-91