RIB NORMAL Manual
RIB NORMAL Manual

RIB NORMAL Manual

Irreversible barrier for vehicular traffic control, with park 230v
Hide thumbs Also See for NORMAL:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 25

Quick Links

NORMAL
Con funzionamento a uomo
presente se le fotocellule o le
coste sono guaste. Conforme alle
normative in vigore.
Avec travail avec homme present,
dans le cas de panne de sécurité.
Conforme aux Normes en vigueur.
With functioning in dead man mode when
the safety devices are failing. According
to current European Norms.
Mit arbeit im mannsbeisein im fall
eines ausfalls der Sicherheiten. In
Übereinstimmung mit der aktuellen
Normen.
Con funcionamiento a hombre presente
en caso de averías con los accesorios de
seguridad. En conformidad a las Normas
en vigor.
ITALIANO pag. 05 / FRANÇAIS pag. 15 / ENGLISH page 25 / DEUTSCH pag. 35 / ESPAÑOL pag. 45
Operatore
Alimentazione
Operateur
Alimentation
Operator
Power Supply
Torantrieb
Stromspannung
Operador
Alimentacion
NORMAL
230V 50Hz
con / avec / with / mit
PARK 230V
BARRIERA IRREVERSIBILE PER IL CONTROLLO DEL
TRAFFICO VEICOLARE
BARRIÈRE IRRÉVERSIBLE POUR LE CONTRÔLE DU
TRAFIC VÉHICULAIRE
IRREVERSIBLE BARRIER FOR VEHICULAR TRAFFIC
CONTROL
SELBSTHEMMENDE SCHRANKE ZUR
VERKEHRSSTEUERUNG
BARRERA IRREVERSIBLE PARA CONTROL DE
TRÁFICO VEHICULAR
Lunghezza max asta
Longueur maxi de la lisse
Max. boom lenght
Max. Baumlänge
Longitud máxima de la asta
6 / 7 m
Codice
Code
Code
Code
Codigo
AA50000

Advertisement

Table of Contents
loading

Summary of Contents for RIB NORMAL

  • Page 1 NORMAL con / avec / with / mit PARK 230V Con funzionamento a uomo presente se le fotocellule o le coste sono guaste. Conforme alle normative in vigore. Avec travail avec homme present, BARRIERA IRREVERSIBILE PER IL CONTROLLO DEL dans le cas de panne de sécurité.
  • Page 2 (par exemple en l’installant dans un cadre fermé à clé). 2° - Per la sezione ed il tipo dei cavi la RIB consiglia di utilizzare un cavo di tipo 2° - Pour la section et le type des câbles, la RIB conseille d’utiliser un câble de type H05RN-F con sezione minima di 1,5 mm 2 e comunque di attenersi alla norma IEC H05RN-F ayant une section minimum de 1,5 mm 2 et de toute façon s’en tenir...
  • Page 3: Installation

    (for example by installing inside a locked board). einer ungewollten Schließung (z.B. wenn sie in einer abgeschlossenen Schalttafel 2° - For the section and the type of the cables, RIB advices to use a cable of the installiert ist).
  • Page 4 (por ejemplo instalándolo dentro de un panel cerrado a llave). 2° - Para la sección y el tipo de los cables, la RIB aconseja utilizar cables de tipo H05RN-F con sección mínima de 1,5 mm 2 e igualmente atenerse a la norma IEC 364 y a las normas de instalación del propio país.
  • Page 5: Caratteristiche Tecniche

    LAYOUT IMPIANTO Barriera NORMAL - Fotocellule di sicurezza - Colonnina portafotocellula zincata - Fotocosta - Sensore magnetico - Selettore a chiave - Antenna radio Misure in mm - Pulsante d’emergenza CARATTERISTICHE TECNICHE CARATTERISTICHE NORMAL TECNICHE Motoriduttore irreversibile ambidestro utilizzato per movimentare aste lunghe fino a 6-7 m.
  • Page 6 Componenti da installare secondo la norma EN12453 Dopo aver cementato il basamento di fissaggio nella posizione da Voi ritenuta ideale, USO DELLA CHIUSURA procedete nel fissaggio della NORMAL utilizzando i dadi in dotazione e una chiave esagonale TIPO DI COMANDO Persone esperte Persone esperte n°...
  • Page 7 REGOLAZIONE MOLLA DI BILANCIAMENTO La barriera viene fornita con le molle di bilanciamento già registrate. In caso vengano aggiunti pesi all’asta (es. coste pneumatiche o a fotocellula) è necessario ribilanciare l’asta. Se l’asta durante il movimento di discesa tende a precipitare, agire sulle molle di bilanciamento. Per far ciò...
  • Page 8: Collegamenti Elettrici

    COLLEGAMENTI ELETTRICI PARK CRX cod. AC07063 CONDENSATORE MOTORE LAMPEGGIATORE ALIMENTAZIONE 230Vac 50 Hz ANTENNA CALZA PASSO PASSO BUZZER ANTENNA R=2K2 STOP CHIUDE APRE 1 APRE 2 OK CHIUDE 12 Vdc max 0,5A per ACCESSORI 12 Vdc max 0,5A per AUTOTEST PER COSTA COSTE FOTOCEL.
  • Page 9 PROBE Morsettiera per collegamento sonda riscaldatore (cod. ACG4666 DIP12 ON per installazioni della scheda PARK 230V su opzionale) barriere NORMAL. RADIO Modulo radio incorporato AUX. ATT. Connettore per scheda 1 relè (cod. ACQ9080) per gestione luce di cortesia o gestione magnete blocco asta. Connettore per scheda SW RADIO NON TOCCARE IL PONTICELLO ! SE VIENE RIMOSSO IL 3 relè...
  • Page 10 - La sbarra rimane ferma nel punto in cui è avvenuto il black-out 6 - Riposizionare DIP 1 su OFF e DIP 2 su OFF. DIP 11 7 - Fine procedura. per sbarra NORMAL PROCEDURA CANCELLAZIONE TOTALE CODICI RADIO DIP 12 La segnalazione si può ottenere solo con la barriera totalmente chiusa.
  • Page 11 ANTENNA MODALITA’ NORMALE I tempi di pausa prima di avere la chiusura DIP 6 OFF automatica della sbarra vengono registrati durante la PASSO PASSO CALZA BUZZER programmazione dei tempi. ENTRATA R=2K2 ANTENNA STOP Il tempo di pausa massimo è di 5 minuti. CHIUDE Il tempo di pausa è...
  • Page 12 FUNZIONAMENTO ACCESSORI DI SICUREZZA DIP 13 OFF => Il lampeggiatore viene alimentato a tensione fissa, pertanto su barriere NORMAL o INDUSTRIAL collegare un lampeggiatore SPARK con scheda FOTOCELLULA (Com - Photo) intermittente incorporata (ACG7059). In allarme da costa o autotest costa Con sbarra abbassata, se un ostacolo è...
  • Page 13 OPTIONAL Per i collegamenti ed i dati tecnici degli accessori attenersi ai relativi libretti di istruzione. ASTA 6 m OTTAGONALE TELESCOPICA ASTA 7 m OTTAGONALE TELESCOPICA Asta 6 m ottagonale telescopica con mozzo L = 3+3 m. Asta 7 m ottagonale telescopica con mozzo L = 4+3 m. cod.
  • Page 14 PALETTO PENDULO PALETTO DI SUPPORTO SCHEDA OPZIONALE A 3 RELÉ PER LUCE BOX o ELETTROMAGNETE E GESTIONE SEMAFORO cod. ACQ9081 SENSORE A SPIRA MAGNETICA Per apertura con automezzi monocanale - 230 Vac cod. ACG9060 monocanale - 12÷24 Vac/dc cod. ACG9063 bicanale - 12÷24 Vac/dc cod.
  • Page 15: Caracteristiques Techniques

    SCHÉMA DÉTAILLÉ DE L’INSTALLATION Barrière NORMAL - Photocellules p/protection - Poteau zingué p/cellule - Fotocosta - Boucle magnetique - Selecteur - Antenne radio Mesures en mm - Arre d’urgence CARACTERISTIQUES TECHNIQUES CARACTERISTIQUES NORMAL TECHNIQUES Motoréducteur irréversible «ambidextre» utilisé pour actionner des lisses pouvant atteindre jusqu’à...
  • Page 16 MONTAGE DE LA NORMAL Parties à installer conformément à la norme EN12453 Après avoir cémenté la plaque de fixation à l’endroit voulu, procéder à la fixation de la NORMAL USAGE DE LA FERMETURE en se servant des écrous en dotation et d’une clé n° 19 à 6 pans.
  • Page 17 RÉGLAGE DES RESSORTS D’ÉQUILIBRAGE Lorsque la barrière est livrée, les ressorts d’équilibrage sont déjà réglés. En cas de rajout de poids à la lisse (ex. cordons pneumatiques ou avec photocellule), il est indispensable de rééquilibrer cette dernière. Si la lisse a tendance à tomber pendant le mouvement de descente, agir sur les ressorts d’équilibrage.
  • Page 18: Branchements Électriques

    BRANCHEMENTS ÉLECTRIQUES PARK CRX code AC07063 CONDENSATEUR MOTEUR FEU CLIGNOTANT ALIMENTATION 230Vac 50 Hz ANTENNE ENVELOPPE PAS A PAS BUZZER ANTENNE R=2K2 STOP FERME OUVRE 1 OUVRE 2 OK FERME 12 Vdc max 0,5A pour ACCESSOIRES 12 Vdc max 0,5A pour AUTOTEST POUR CORDON DE SICURITE CORD.
  • Page 19 K2 => Commande de direction de la fermeture - Fonctionnement en mode PARK Q4 => TRIAC - Commande moteur en ouverture et en fermeture - Fonctionnement en mode NORMAL Q5 => Commande du feu clignotant ATTENTION: LA CARTE PARK PAR L’INTERMÉDIAIRE DE DIP 6 ACTIVE OU NON CERTAINES COMMANDES, PAR CONSÉQUENT, IL EST À...
  • Page 20 - Programmation radio activée C - MONTRÔLE DU SENS DE ROTATION DU MOTEUR FONCTIONNEMENT DES ACCESSOIRES DE COMMANDE EN MODE NORMAL Ce contrôle a pour but d’aider l’installateur lors de la mise en place de l’installation ou lors d’éventuels contrôles futurs.
  • Page 21 TÉLÉCOMMANDE ANTENNE MODE NORMAL DIP4 OFF => Effectue une commande cyclique des DIP 6 OFF PAS A PAS ENVELOPPE commandes ouvre-stop-ferme-stop- BUZZER ENTRÉE R=2K2 ANTENNE STOP ouvre-etc. DIP4 ON => Procède à l’ouverture lorsque la lisse FERME est fermée. S’il est actionné lors de OUVRE 1 l’ouverture, il ne produit aucun effet.
  • Page 22 433,92MHz la fermeture de la barrière n’est pas possible. Il est possible de rétablir le fonctionnement - Impédance 52 Ω normal uniquement en redressant la barre palpeuse et en pressant l’une des commandes - Sensibilité > 2,24µV appropriées. - Temps de mise en tension...
  • Page 23 OPTIONS Pour les branchements et les données techniques des accessoires, se conformer aux livrets d’instruction correspondants. TIGE DE 6 m OCTOGONALE TELESCOPIQUE TIGE DE 7 m OCTOGONALE TELESCOPIQUE Tige de 6 m octogonale télescopique avec moyeu L = 3+3 m. Tige de 7 m octogonale télescopique avec moyeu L = 4+3 m.
  • Page 24 FOURCHE ESCAMOTABLE PIEU DE SUPPORT CARTE EN OPTION À 3 RELAIS POUR BOîTE DE LUMIÈRE OU ÉLECTROAIMANT ET GESTION DES FEUX code ACQ9081 CAPTEUR À SPIRE MAGNÉTIQUE Pour ouverture avec véhicules automobiles monocanal - 230 Vac code ACG9060 monocanal - 12÷24 Vac/dc code ACG9063 deux canaux - 12÷24 Vac/dc code ACG9064...
  • Page 25: System Layout

    SYSTEM LAY-OUT 181,10” 2755,90” 118,11” NORMAL barrier Measurements in mm/inch - Photoelectric cells - Galvanized column for P.E. cells - Fotocosta - Magnetic loop TECHNICAL - Key selector NORMAL DATA - Tuned aerial - Emergency button Max. boom lenght Opening time Max.
  • Page 26: Adjusting The Limit Switches

    ASSEMBLING THE NORMAL BARRIER Parts to install meeting the EN 12453 standard After having cemented the fixing base in the position you prefer, fix the NORMAL unit, using USE OF THE SHUTTER the nuts supplied and a setscrew wrench n. 19.
  • Page 27: Emergency Release

    ADJUSTING THE BALANCING SPRING The barrier is supplied with its balancing springs already adjusted. If extra weights are added to the barrier boom (e.g. pneumatic or photocell-type safety strips), you need to balance the boom again. If the boom tends to drop quickly when it moves down, modify the balancing springs.
  • Page 28 ELECTRIC CONNECTIONS PARK CRX code AC07063 CAPACITOR MOTOR BLINKER POWER SUPPLY 230Vac 50 Hz COAX K BUTTON BUZZER R=2K2 STOP CLOSE OPEN 1 OPEN 2 OK CLOSE 12 Vdc max 0,5A for ACCESSORY SUPPLY 12 Vdc max 0,5A for AUTOTEST EDGE EDGE PHOTO...
  • Page 29 OFF - Operation in NORMAL MODE DIP 15 ON for NORMAL barrier WARNING: DIP 16 OFF for NORMAL barrier The PARK MODE enables or disables some features and commands: - If NORMAL MODE is enabled, OPEN2 command, OK CLOSE command and TLC LED WARNING...
  • Page 30 DL2 - Stop contact (red) DL3 - Barrier opening (green) DL4 - Barrier closing (red) FUNCTIONING OF CONTROL ACCESSORIES in NORMAL MODE (DIP6 OFF) DL5 - Photocells contact (red) ATTENTION: ONLY IMPULSIVE COMMANDS HAVE TO BE CONNECTED. DL6 - Safety strip contact (red) Make sure that any other type of command accessories (e.g.
  • Page 31 OKCLOSE INPUT (COM - OKCLOSE) (ONLY PARK MODE) an OK CLOSE impulse to the control board (the OK CLOSE command can be connected to the If the NORMAL MODE is enabled (DIP6 OFF), the OKCLOSE command will be disabled. NO contact of the photocell receiver).
  • Page 32 (if connected) enabled for 5 minutes, get into action. In this case the gate cannot - Voltage available on the radio connector 200mA 12Vdc open and normal functions are reinstated only upon repair of the safety edge and by pressing one of the enabled switches. RADIO TECHNICAL FEATURES - Reception frequency 433.92MHz...
  • Page 33: Base Plate

    ACCESSORIES For the connections and the technical data of the optional equipments follow the relevant handbooks. TELESCOPIC OCTAGONAL BOOM ARM, 6 m TELESCOPIC OCTAGONAL BOOM ARM, 7 m Telescopic octagonal boom arm and fixing hub L = 3 + 3 m. Telescopic octagonal boom arm and fixing hub L = 4 + 3 m.
  • Page 34 HANGING SUPPORT FORK TYPE SUPPORT THREE RELAY EQUIPPED OPTIONAL CARD FOR BOX LIGHT OR ELECTROMAGNET AND TRAFFIC LIGHT CONTROL code ACQ9081 METALLIC MASS DETECTOR to open with vehicles 1 channel - 230 Vac code ACG9060 1 channel - 12÷24 Vac/dc code ACG9063 2 channels - 12÷24 Vac/dc code ACG9064...
  • Page 35: Technische Daten

    ANLAGEN LAY-OUT NORMAL Schranke - Photozellen - Verzinkte Metallsäule als Photozellenträger - Fotokontaktleiste - Magnetschleife - Schlüsselschalter - Antenne Abmessungen in mm - Notschalter TECHNISCHE DATEN TECHNISCHE NORMAL EIGENSCHAFTEN Selbsthemmender, auf beiden Seiten montierbarer Getriebemotor zum Antrieb von Schrankenbäumen Max. Baumlänge mit Länge bis zu 6-7 m.
  • Page 36: Einstellung Der Endschalter

    INSTALLATION NORMAL MONTAGE DER NORMAL-EINHEIT Komponenten zur Installation nach der Norm EN1253 Nach der Zementeinbettung des Sockels in einer geeigneten Position die Normal-Einheit mit ANWENDUNG DER SCHLIESSUNG den gelieferten Muttern und einem Sechskanteinsteckschlüssel Nr. 19 befestigen. Fachpersonen STEUERUNGSSYSTEM Danach den Schrankenbaum in vier Schritten montieren:...
  • Page 37 EINSTELLUNG DER AUSGLEICHSFEDER Die Schranke wird mit bereits eingestellten Ausgleichsfedern geliefert. Werden dem Schrankenbaum zusätzliche Gewichte angesetzt (z.B. pneumatische- oder Fotokontaktleisten), muß er neu ausgewuchtet werden. Wenn der Schrankenbaum dazu neigt, sich zu schnell zu senken, muß auf die Ausgleichsfedern eingewirkt werden.
  • Page 38 ELEKTROANSCHLÜSSE PARK CRX Kode AC07063 KONDENSATOR MOTOR BLINKER SPEISUNG 230Vac 50 Hz ANTENNE BEFLECHTUNG SCHRITT BEI SCHRITT BUZZER ANTENNE R=2K2 STOP SCHLIESSE ÖFFNE 1 ÖFFNE 2 OK SCHLIESSE 12 Vdc max 0,5A für ZUBEHÖRE 12 Vdc max 0,5A für AUTOTEST FÜR GELENKRIPPE RIPPE FOTOZEL.
  • Page 39 DIP12 ON zur Installierung der Karte PARK 230V AUX. ATT. Steckverbinder für Platine 1 Relais (Kode ACQ9080) zum NORMAL Schranken. Betrieb Funktionsbeleuchtung oder zum Betrieb Magnet Schrankenbaumsperre. Steckverbinder für Platine 3 Relais (Kode ACQ9081) zum Betrieb Funktionsbeleuchtung oder zum Betrieb SW RADIO NICHT DIE ÜBERBRÜCKUNG BERÜHREN! OHNE ANTRIEB NICHT...
  • Page 40: Led-Anzeigen

    5 - Um die Programmierung abzuschließen, 10 sec. warten oder unmittelbar den Taster DIP 11 “PROG” drücken. Die LED-Programmier-Anzeige “DL1” blinkt auf. - für NORMAL Schranke 6 - “DIP 1” wieder auf “AUS” zurückstellen und “DIP 2” auf “AUS”. DIP 12 7 - Abschluss der Programmierphase.
  • Page 41 STANDARDBETRIEB ANTENNE Schranke. Wenn diese Taste während DIP 6 OFF einer Schließbewegung betätigt wird, SCHRITT BEI SCHRITT BEFLECHTUNG BUZZER führt dies zur erneuten Öffnung der EINFAHRT R=2K2 ANTENNE STOP Schranke. SCHLIESSE FERNSTEUERUNG ÖFFNE 1 DIP4 - OFF => Führt einen Befehl der Steuerreihe Öffnen - Stopp - Schließen - Stopp - Öffnen usw.
  • Page 42 Funktion oder Schritt für Schritt restauriert, und damit auch die Fernbedienung schließt => Teilweise geschlossene Schranke => Nach erfolgter und das automatische Schließen wieder möglich. Schließung funktionieren alle Funktionen wieder normal. Während Anmerkung 1: Während dieses Vorgangs, im fall eines ausfalls der Kontaktleisten der Wiederangleichung bleiben alle Sicherheitseinrichtungen aktiv.
  • Page 43 OPTIONEN Für die Anschlüsse und die technischen Daten der Zubehöre verweisen wir auf die entsprechenden Betriebsanleitungen. TELESKOPISCHE ACHTECK-STANGE 6 m TELESKOPISCHE ACHTECK-STANGE 7 m Teleskopische Achteck-Stange 6 m mit Nabe L = 3 + 3 m. Teleskopische Achteck-Stange 7 m mit Nabe L = 4 + 3 m. Kode ACG8513 Kode ACG8514 HÄNGEGITTER...
  • Page 44 STÜTZPENDEL ABSTÜTZ TRÄGER FAKULTATIVE PLATINE MIT 3 RELAIS FÜR LICHT BOX ODER ELEKTROMAGNET UND BETRIEBSAMPELANLAGE Kode ACQ9081 MAGNETWINDUNGSSENSOR Für Öffnung mit Fahrzeugen Einkanalig - 230 Vac Kode ACG9060 Einkanalig - 12÷24 Vac/dc Kode ACG9063 Zweikanalig - 12÷24 Vac/dc Kode ACG9064 Hänge Stütze mit Regulierung der Höhe Gabelförmiger Abstützträger, nutzbar für Achteck-Stangen.
  • Page 45: Características Técnicas

    DISPOSICIÒN DE LA INSTALACIÒN Barrera NORMAL - Fotocélulas de seguridad - Pilar galvanizado soporte fotocélula - Fotonervadura - Sensor magnético - Selector con llave - Antena de radio Medidas en mm - Pulsador de urgencia CARACTERÍSTICAS TÉCNICAS CARACTERÍSTICAS NORMAL TÉCNICAS Motorreductor irreversible ambidiestro, utilizado para mover astas de hasta 6-7 m de longitud.
  • Page 46 INSTALACIÓN NORMAL MONTAJE DE NORMAL Componentes a instalar según la norma EN12453 Una vez cementada la base en la posición elegida, fijar a ella la barrera NORMAL con las USO DEL CIERRE tuercas respectivas, utilizando una llave hexagonal Nº 19.
  • Page 47 REGULACIÓN DE LOS RESORTES DE EQUILIBRIO Normalmente, la barrera se entrega con los resortes de equilibrio yá regulados. Si se añade algún peso al asta (ej., bandas neumáticas o fotoeléctricas), es necesario volverlo a equilibrar. Si la asta tira a caer durante el movimiento de bajada, arreglar los resortes de la siguiente manera: Para ello, subir la asta de modo eléctrico o manual hasta la posición vertical y efectúe la regulación con una llave hexagonal Nº...
  • Page 48 CONEXIONES ELÉCTRICAS PARK CRX code AC07063 CONDENSADOR MOTOR INTERMITENTE ALIMENTACION 230Vac 50 Hz ANTENA MASA PASSO PASSO BUZZER ANTENA R=2K2 STOP CIERRA ABRE 1 ABRE 2 OK CIERRA 12 Vdc max 0,5A para ACCESSORIOS 12 Vdc max 0,5A para AUTOTEST PARA COSTA COSTAS FOTOCEL.
  • Page 49 ATENCIÓN: LA TARJETA PARK, A TRAVÉS DEL DIP 6, HABILITA O DESHABILITA ALGUNOS MANDOS, POR LO TANTO, PRESTAR ATENCIÓN: SW1 SW2 - MICROINTERRUPTOR PARA EL PROCEDIMIENTO CUANDO DIP6 ESTÁ EN OFF - FUNCIONAMIENTO NORMAL DIP1 - CONTROL DEL SENTIDO DE ROTACIÓN DEL MOTOR (ON)
  • Page 50 7 - Fin del procedimiento. DIP 11 PROCEDIMIENTO PARA LA CANCELACIÓN TOTAL DE LOS CÓDIGOS DE RADIO - para barrera Normal La programación puede ser efectuada solo con la barrera totalmente cerrada. DIP 12 1 - Colocar el DIP 1 en la posición ON y luego el DIP 2 en ON.
  • Page 51 Si se lo ANTENA MODALIDAD NORMAL acciona con la barra abierta, la cierra. DIP 6 OFF Si se lo acciona durante el movimiento PASSO PASSO MASA BUZZER ENTRADA de cierre, la vuelve a abrir. R=2K2...
  • Page 52 DIP 13 OFF => El intermitente es alimentado con tensión fija, por lo tanto, para barrera Las fotocélulas intervendrán solo en la fase de cierre (con el restablecimiento del movimiento NORMAL o INDSTRIAL conectar un intermitente SPARK con tarjeta inverso luego de un segundo, aún cuando estas permanezcan ocupadas).
  • Page 53 OPCIONALES Para las conexiones y datos técnicos de los accesorios, consultar los manuales respectivos. BARRA 6 m OCTAGONAL TELESCÓPICA BARRA 7 m OCTAGONAL TELESCÓPICA Barra 6 m octagonal telescópica con cubo L = 3 + 3 m. Barra 7 m octagonal telescópica con cubo L = 4 + 3 m. cód.
  • Page 54 VARILLA PÉNDULO VARILLA DE SOPORTE TARJETA OPCIONAL CON 3 RELÉS PARA LUZ BOX O ELECTROIMÁN Y GESTIÓN SEMÁFORO cód. ACQ9081 SENSOR EN ESPIRAL MAGNÉTICA Para la apertura con vehículos monocanal - 230 Vac cód. ACG9060 monocanal - 12÷24 Vac/dc cód. ACG9063 bicanal - 12÷24 Vac/dc cód.
  • Page 55 NOTES...
  • Page 56 NOTES...
  • Page 57: Assistenza Tecnica

    REGISTRO DI MANUTENZIONE - DOSSIER D’ENTRETIEN - MAINTENANCE LOG WARTUNGSREGISTER - REGISTRO DE MANTENIMIENTO Il presente registro di manutenzione contiene i riferimenti tecnici e le registrazioni delle attività di installazione, manutenzione, riparazione e modifica svolte, e dovrà essere reso disponibile per eventuali ispezioni da parte di organismi autorizzati. Ce dossier d’entretien contient les références techniques et les enregistrements des opérations d’installation, d’entretien, de réparation et de modification effectuées, et devra être rendu disponible pour les inspections éventuelles de part d’orgenismes autorisée.
  • Page 58 We declare under our responsibility that NORMAL operator is conform to the following standards: Wir erklaeren das der NORMAL den folgenden EN-Normen entspricht: Declaramos bajo nuestra responsabilidad que los operators NORMAL es conforme a la siguientes normas y disposiciones: EN 301 489-1...
  • Page 59 CMO1219 Rotore Normal BA01510 Contenitore Medium per scheda CME3029 Disco tendimolla CPL1019 Tappo chiusura BA03203 Gruppo PARK 120 per Normal CME3038 Coperchio frizione CTC1041 Molla a tazza 18,3 35,5 2 BA03209 Gruppo PARK 230 per Normal CME3043 Flangia motore CTC1180...
  • Page 60 NORMAL DUO CARD ACG8010 PER IL COMANDO CONTEMPORANEO DI DUE BARRIERE POUR LA COMMANDE SIMULTANÉE DE DEUX BARRIÈRES FOR CONNECTING TWO BARRIERS AT THE SAME TIME FÜR DIE GLEICHZEITIGE BETÄTIGUNG VON ZWEI SCHRANKEN PARA EL MANDO CONTEMPORÁNEO DE DOS BARRERAS...

Table of Contents