RIB NORMAL Manual page 31

Irreversible barrier for vehicular traffic control, with park 230v
Hide thumbs Also See for NORMAL:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 25
OPERATING IN PARK MODE (DIP6 ON)
TO ENTER:
Provided there be a vehicle on the Entry magnetic loop
(see scheme 4), opening can be controlled by pressing
OPEN1, K BUTT or RADIO switch (OPEN1 performs the
boom arm opening only if the TLC, connected to the
Entry Magnetic Loop, contact is closed).
TO EXIT:
Provided there be a vehicle on the Exit magnetic loop
(see scheme 4), opening can be controlled by pressing
OPEN2, K BUTT, RADIO switch. The OPEN2 can be
connected to the Exit magnetic loop.
If the DIP8 is turned ON, the OPEN2 will perform the
barrier opening regardless the presence of a vehicle
at the Entry.
If the DIP8 is turned OFF, the OPEN2 will perform the
barrier opening if there is no vehicle on the magnetic
sensor connected to the TLC input (TLC contact
opened).
In both the conditions, TO ENTER and TO EXIT, from the
complete boom arm open position:
If the Automatic Closing is enabled (DIP3 ON),
the boom arm will close at the end of the delay time
programmed (see Point C).
If the Automatic Closing is disabled, the boom arm
will remain open until a closing command is pressed or
until the vehicle passes in front of the photocells, giving
an OK CLOSE impulse to the control board (the OK CLOSE command can be connected to the
NO contact of the photocell receiver).
OPEN2 BUTTON (COM - OPEN2) (ONLY PARK MODE)
If the NORMAL MODE is enabled (DIP6 OFF), the OPEN2 command will be disabled.
If the PARK MODE is enabled (DIP6 ON), the OPEN2 will perform the boom arm opening
depending on the switch DIP8 position.
If DIP8 is turned ON and PARK MODE is enabled, OPEN2 will perform the boom arm
opening regardless the state of the TLC input.
If DIP8 is turned OFF and PARK MODE is enabled, OPEN2 will perform the boom arm
opening only if the TLC contact is OPEN (no vehicle at the Entry, see scheme 4).
+
K BUTTON
LED
R=2K2
STOP
CLOSE
+
OPEN 1
LSC
LSO
TIMER
AERIAL
+
+
BUZZER
K BUTTON
LED
R=2K2
-
STOP
CLOSE
+
OPEN 1
12 Vdc max 0,5A for ACCESSORY SUPPLY
12 Vdc max 0,5A for AUTOTEST EDGE
OKCLOSE INPUT (COM - OKCLOSE) (ONLY PARK MODE)
closure after the vehicle transit.
receiver or a magnetic sensor device installed along the boom arm closing line. The vehicle
will engage the contact when it reaches the closing line. The boom arm will close as soon as
the vehicle left the closing line and the contact is released.
TRAFFIC LIGHT CONTROL (COM - TLC) (ONLY PARK MODE)
The TLC input can be connected to the Entry magnetic loop device (see scheme 4). The
OPEN1 command is enabled only if the TLC input is closed, presence of a vehicle at the
31
AERIAL
+
COAX
BUZZER
-
_
_
12 Vdc max 0,5A for ACCESSORY SUPPLY
+
_
12 Vdc max 0,5A for AUTOTEST EDGE
+
COAX
_
+
_
+
If the NORMAL MODE is enabled (DIP6 OFF), the OKCLOSE command will be disabled.
If the PARK MODE is enabled (DIP6 ON), the OKCLOSE will perform the boom arm
Usually, this command is connected to the Normally Open contact from a photocell
STANDARD OPERATION
DIP 6 OFF
ENTRY
EDGE
NC
NO
COM
S
S
D-
D-
D
+
D
MAGNETIC LOOP
TO EXIT
PARK OPERATION
DIP 6 ON
MAGNETIC LOOP
TO ENTRY
EDGE
NC
NO
COM
S
S
D-
D-
D+
D+
MAGNETIC LOOP
TO EXIT
G
B

Advertisement

Table of Contents
loading

Table of Contents