1.
Place Key in Ignition Switch.
2.
Disengage the driving unit, or if equipped, put the trans-
mission in NEUTRAL.
3.
With the accelerator pedal or lever in the idle position,
turn the keyswitch to the ON position.
4.
When the ignition is turned on, the display powers up and
defaults to GAUGE DISPLAY mode. The display should re-
main in this mode for normal operation.
Figure 67. Gauge Display Mode
5.
Under cold conditions, the Wait-to-Start indicator will illu-
minate at Ignition Switch ON position, and will stay on for
a period of up to 30 seconds.
6.
Turn key in Ignition Switch clockwise to START position.
7.
Release key immediately after the engine starts. The Igni-
tion Switch will automatically return to RUN.
Figure 68. Turn Key in Ig-
nition Switch to START.
Release the key immediately once the motor starts. If the
motor does not start, DO NOT crank the starter motor con-
tinuously for more than 15 seconds. Failure to release the
key after the motor has started or continuous cranking can
damage the starter motor.
8.
After the engine starts, allow the engine to idle for ap-
proximately 60 seconds.
Operation Manual
Operation Manual
Figure 69. Ignition Switch Automati-
cally Returns to RUN When Released
Caution
9.
Apply the service brake pedal and disengage the Parking
Brake switch.
NOTE: If the engine fails to start on the first try, wait until the
engine and starter come to a complete stop before cranking
the engine again.
The engine must have adequate oil pressure within 15 sec-
onds after starting. If the WARNING lamp indicating low oil
pressure has not gone out or there is no oil pressure indi-
cated on a gauge within 15 seconds, shut OFF the engine
immediately to avoid engine damage.
10. Idle the engine 3 to 5 minutes before operating with a
load. After starting a cold engine, increase the engine
speed (rpm) slowly to provide adequate lubrication to the
bearings and to allow the oil pressure to stabilize.

Jump Starting

Jump Start or replace the battery of the Telehandler when
the battery is discharged to the point that it will not crank the
starter.
Lead-acid batteries produce flammable and potentially ex-
plosive gases. To avoid death or serious injury when check-
ing, testing, or charging batteries:
DO NOT use smoking materials near batteries.
Keep arcs, sparks, and open flames away from batteries.
Provide ventilation for flammable vapors.
Wear proper personal protective equipment, including
safety glasses.
Fluid in electric storage batteries contains sulfuric acid,
which is poison and could cause severe chemical burns.
Avoid all contact of fluid with eyes, skin, or clothing. Use
protective gear when handling batteries. DO NOT tip a bat-
tery beyond a 45° angle in any direction.
If contact does occur, follow these First Aid suggestions:
External contact - Flush with water.
52