Fluorescent Lamp - Toshiba Tecra M1 Maintenance Manual

Personal computer
Hide thumbs Also See for Tecra M1:
Table of Contents

Advertisement

4.25 Fluorescent Lamp

4
4.25 Fluorescent Lamp
This system uses LCD modules from the following suppliers. The procedure for replacing the
fluorescent lamp is different for each LCD module. Refer to the appropriate procedure.
Type
14.1-inch (XGA)
14.1-inch (SXGA+)
NOTE: - When working with an LCD module, always use a flat, grounded table.
- Handle the backlight unit in the environment without dust, such as on the clean
bench. Keep the worktable free from any screws or other material that may
scratch the LCD surface.
- Use an anti-static or protective sheet.
- When replacing the FL unit, cover with a finger protector or similar to prevent
soiling or scratching the LCD panel.
- Be careful when handling the lamp. Excessive force may break the lamp.
- Be careful not to soil or deform the lamp reflector.
- Make sure that the power of the LCD module is turned off before connecting
or disconnecting cables and connectors.
TECRA M1 Maintenance Manual (960-436)
Part No.
VF2092P03
TOSHIBA
VF2074P01
Sharp
4 Replacement Procedure
Supplier
Section
4.25.1
4.25.2
4-85

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents