Start Screen; Setup Menu - Dräger RVP 5000 Technical Handbook

Display for connection to dräger regard
Hide thumbs Also See for RVP 5000:
Table of Contents

Advertisement

Available languages

Available languages

Start screen

7
Start screen
The start screen displays a red banner "Please Wait" which
shows that the unit is initializing. The initialization can take up
to 2 minutes based on the loading configuration. The last 30
seconds of the initialization is visible by a run down of the
banner. The banner disappears after ending of initialization.
The screen displays a maximum of 10 out of 99 possible
channels. Each channel will be represented with a channel
number, measured value, unit, gas, A1, A2 (A3, if configured -
otherwise hidden) and the channel name.
There are different types of channel selection. The direct input
of channel number or select more than ten blocks and using
the scroll buttons.
The status messages of individual channels will be color coded
for the corresponding status fields (e.g. channel 2 status
message A1 + A2 .. the fields A1 + A2 in channel 2 are red
flashing).
All channels have several preset status messages; Inhibit
(locking alarm in the current state), Fault (yellow), FSD
(overrange - red), FLTC (Fault communication/No Respond-
yellow), HCAL (Head calibration - yellow).
The display will jump automatically to any channel which
displays an alarm, fault or inhibit status. A coloured dash will
also be shown under the group button (3). Red for alarm and
yellow for fault or inhibit. As the alarm status information
carries the most importance there may be a slight delay in the
actual gas reading if there are a number of alarm triggered at
the same time. If there is a communication error between the
Dräger RVP 5000 and the REGARD system there will be
shown 8 small dashes instead of the measuring value.
.
8
1
2
3
4
1 Channel selection by scroll button - single or ten steps
2 Internal horn off
3 Channel selection by 10x key block
4 Event window screen
5 Alarm acknowledgment of Regard Systems (only at Mod-
bus V.2.0, NON ATEX
6 System setting screen
7 Direct channel selection
8 By touch on logo: Pop-up window showing the software revi-
sion (the window will close after 10 seconds automatically).
9 Internal horn reset
28
8
The Setup menu enables access to the various setting options
on the RVP 5000. Some of these functions are password-
protected for security reasons.
1 Entering the password and subsequent release of the other
2 Disable the password-protected areas
3 Internal testing and adjustment of the touch panel
4 Language
5 Information and configuration of network settings (only
6 Setting the current date, current time and customer speci-
7 Import of the Regard System configuration, asset descrip-
8 Setting the data store (only SC00091 and SC00092)
9 Select the user (Operator, Configurator, Administrator)
7
6
9
5
00133194_en.eps

Setup menu

1
2
3
password-protected functions
SC00092)
fied passwords
tion, version setting at the Modbus card
4
5
6
7
8
9
00233141_en.eps
Dräger RVP 5000

Advertisement

Chapters

Table of Contents
loading

Table of Contents