Dräger RVP
Communication
System Center Lübeck

Advertisement

loading

Summary of Contents for Dräger RVP 2400

  • Page 1 Dräger RVP Communication System Center Lübeck...
  • Page 2: Table Of Contents

    Dräger RVP - Communication Content Introduction Network Cable RVP 2400 RVP 3900 RVP 5000 Remote Communication 2 | Dräger RVP - Communication | Middelborg/Olsson | November 2011...
  • Page 3: Introduction

    Every variant has a different way of communication to its connected controller. We will show the different types of communication for the RVP 2400, RVP 3900 and RVP 5000. 3 | Dräger RVP - Communication | Middelborg/Olsson | November 2011...
  • Page 4: Network Cable

    Dräger RVP - Communication Network Cable There are 5 different norms of network cable in the world. As shown in the table below each type uses different colours. The cable type in the manuals of the RVP's and this presentation refer to the EIA/TIA 568B norm. Cable pair EIA/TIA 568A EIA/TIA 568B...
  • Page 5: Rvp 2400

    Dräger RVP - Communication RVP 2400 The RVP 2400 can be connected to up of 5 Regard 24xx / RailGard-XX Controller to visualize the data. A configuration on the RVP 2400 is not necessary. The addressing will be done via the Regard 24x0 configuration software.
  • Page 6 Baud rate, Bits, Parity and Stop bit must not be changed. The default settings are 19200/8N1. The controller will be visible on the RVP 2400 with the same numbers addressed in the configuration software. 6 | Dräger RVP - Communication | Middelborg/Olsson | November 2011...
  • Page 7 The Regard 24xx / RailGard-XX controller will be connected to the internal or external converter (SC00041 / SC00042). The converter transforms the incoming signals of the controller from RS232 to RS485. The RVP 2400 gets the data from the RS485 interface and make them visible on the screen.
  • Page 8 Dräger RVP - Communication RVP 2400 Connection of the converter colour of cable orange/white: RJ45 jack PIN 1 (TxB) → Converter connector A colour of cable orange: RJ45 jack PIN 2 (TxA) → Converter connector B colour of cable green: RJ45 jack PIN 6 →...
  • Page 9: Rvp 3900

    Dräger RVP - Communication RVP 3900 The RVP 3900 is able to display data of up to 8 Regard 3900/3910 controller. RS-485 max 1,2 Km 9 | Dräger RVP - Communication | Middelborg/Olsson | November 2011...
  • Page 10 Dräger RVP - Communication RVP 3900 Example: RVP 3900, connected to 2 Regard 3910 systems System 1 CAN Bus intern System 2 RS 485 / Modbus 10 | Dräger RVP - Communication | Middelborg/Olsson | November 2011...
  • Page 11 Dräger RVP - Communication RVP 3900 Internal the Regard 39x0 system communicates via the CAN Bus protocol. To make it possible to visualize these data on the RVP 3900 they first have to be transformed to the Modbus RTU protocol. This will be done by the Regard 3900 Modbus Gateway (SC00083).
  • Page 12 Dräger RVP - Communication RVP 3900 Regard 3900 Modbus Gateway Overview Connectors: 12 | Dräger RVP - Communication | Middelborg/Olsson | November 2011...
  • Page 13 Dräger RVP - Communication RVP 3900 Communication Regard 3900 Connection: Regard 3900 Modbus Gateway Regard 3900 Cable Gateway Modbus Gateway → PIN 2 High (SC00083) → PIN 4 Connection Regard 3900 Modbus Gateway cable to Regard 3900 display board (Connector for Regard 3900 Configuration Cable) Dräger Regard 3900 display board...
  • Page 14 Dräger RVP - Communication RVP 3900 Communication Regard 3910 Connection: Regard 3900 Modbus Gateway Cable Gateway Regard 3900 → Modbus Gateway PIN 2 (SC00083) → PIN 3 High Connection Regard 3910 Modbus Gateway cable to Regard 3910 internal system bus cable Regard 3900/3910 ribbon cable Connector for Regard 3900...
  • Page 15 Dräger RVP - Communication RVP 3900 Communication Regard 3900 Modbus Gateway RVP 3900 orange/white: RJ45 jack PIN 1 (TxB) → Gateway RS485 "+" orange: RJ45 jack PIN 2 (TxA) → Gateway RS485 "-" 15 | Dräger RVP - Communication | Middelborg/Olsson | November 2011...
  • Page 16 Dräger RVP - Communication RVP 3900 Addressing the Regard 3900 Modbus Gateway: Every gateway has to be addressed before it can be used. Procedure: Set 'Boot' Jumper from Pos. 2 to Pos. 3 (without power supply). Connect to power supply (yellow LED will blink fast).
  • Page 17: Rvp 5000

    Dräger RVP - Communication RVP 5000 Das RVP 5000 get's the required data from the Modbus Gateway Card. In the standard application the RVP 5000 is able to visualize up to 99 channel from only 1 Regard system. As the Regard system only transfers status messages and values and not any data of the system configuration the RVP 5000 needs a configuration file.
  • Page 18 Dräger RVP - Communication RVP 5000 Creating the configuration file via the REGARD Configuration software: Login into Service Level load/create a system configuration click button "Export to CSV" choose file name (max. 8 digits) and save csv file Copy file onto the CF card of the RVP 5000(via card reader or USB connection to unit) 18 | Dräger RVP - Communication | Middelborg/Olsson | November 2011...
  • Page 19 Dräger RVP - Communication RVP 5000 Loading the configuration file on the RVP 5000: Login as administrator in the menu "Settings". Touch the button "Import Configuration". Touch the field below "File Name" and type in the file name with extension ".csv". Touch the button "Import-Conf".
  • Page 20 Dräger RVP - Communication RVP 5000 Configuration Menu of the Modbus Gateway Card: Settings Modbus Card Command No. Command Name Function Default Settings Software version V 1.9 00-0 QUIT Leave command mode 00-1 P.WD Enter password CCCC 00-2 SAVE Save settings 00-3 PCHG Change password...
  • Page 21 Dräger RVP - Communication RVP 5000 REGARD Modbus Interface Card Connection RS485: Jack on RS485 Port of RVP 5000 21 | Dräger RVP - Communication | Middelborg/Olsson | November 2011...
  • Page 22: Remote Communication

    Slave unit required. The cable for this connection is a standard LAN cable (CAT5 or higher). The data can be shown individual on both panels. The Remote solution is also possible with the RVP 2400 and RVP 3900 22 | Dräger RVP - Communication | Middelborg/Olsson | November 2011...
  • Page 23 Dräger RVP - Communication Remote Communication RVP 5000 Slave Connection Schematic Regard RS485 System D räger D räger D räger D räger D räger D räger D räger D räger D räger REGARD REGARD REGARD REGARD REGARD REGARD REGARD REGARD REGARD RS485 Shift...
  • Page 24 Dräger RVP - Communication Communication Solutions RVP 2400/3900/5000: Internal RS485 output card 24 | Dräger RVP - Communication | Middelborg/Olsson | November 2011...
  • Page 25 Dräger RVP - Communication Communication Solutions RVP 2400: Internal Profibus-DP output card 25 | Dräger RVP - Communication | Middelborg/Olsson | November 2011...
  • Page 26 Dräger RVP - Communication Communication Solutions Regard 39X0: Regard 3900 Profibus-DP Gateway (for the communication to a PLC) 26 | Dräger RVP - Communication | Middelborg/Olsson | November 2011...
  • Page 27 Dräger RVP - Communication Communication Solutions Regard 3900 / RVP 3900: Regard 3900 Modbus TCPIP Gateway (to connect to a RVP or PLC via network) 27 | Dräger RVP - Communication | Middelborg/Olsson | November 2011...
  • Page 28 Dräger RVP - Communication Communication Solutions RVP 5000 with more than 1 Regard system and/or more than 99 channels (via Regard Netbox) D räger D räger D räger D räger D räger D räger D räger D räger D räger D räger D räger D räger...
  • Page 29 Thank You! 29 | Dräger RVP - Communication | Middelborg/Olsson | November 2011...