SMC Networks PFM3 Series Operation Manual

Flow monitor
Hide thumbs Also See for PFM3 Series:

Advertisement

Quick Links

No.PF##-OMJ0018
Flow Monitor
PRODUCT NAME
PFM3## Series
MODEL / Series

Advertisement

Table of Contents
loading

Summary of Contents for SMC Networks PFM3 Series

  • Page 1 No.PF##-OMJ0018 Flow Monitor PRODUCT NAME PFM3## Series MODEL / Series...
  • Page 2: Table Of Contents

    Table of Contents Safety Instructions Model Indication Method Names and Functions of Individual Parts Definition and terminology Mounting and Installation Installtion Wiring Flow setting Function setting Setting at the shipment from a factory F0 Setting of autopreset F1 Operation of OUT1 F2 Operation of OUT2 F3 Select operating fluid F4 Display unit selection...
  • Page 3: Safety Instructions

    Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of "Caution", "Warning" or "Danger". They are all important notes for safety and must be followed in addition to International standards (ISO/IEC), Japan Industrial Standards (JIS) and other safety regulations *1) ISO 4414: Pneumatic fluid power - - General rules relating to systems.
  • Page 4 Caution 1. The product is provided for use in manufacturing industries. The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch.
  • Page 5 Operator ♦This operation manual has been written for those who have knowledge of machinery and apparatus that use pneumatic equipment and have full knowledge of assembly, operation and maintenance of such equipment. ♦Please read this operation manual carefully and understand it before assembling, operating or providing maintenance to the product.
  • Page 6 ■NOTE ○Follow the instructions given below when designing, selecting and handling the product. ●The instructions on design and selection (installation, wiring, environment, adjustment, operation, maintenance, etc.) described below must also be followed. ∗Product specifications •The direct current power supply to combine should be UL approved as follows. Circuit (of class 2) which is of maximum 30Vrms (42.4 V peak) or less, with UL 1310 class 2 power supply unit or UL 1585 class 2 transformer.
  • Page 7 ∗Wiring •Do not pull the lead wires. In particular, never lift a product equipped with fitting and piping by holding the lead wires. Otherwise damage to the internal parts can result, causing malfunction or to be off the connector. •Avoid repeatedly bending or stretching the lead wire, or placing heavy load on them. Repetitive bending stress or tensile stress can cause the sheath of the wire to peel off, or breakage of the wire.
  • Page 8 ∗Environment •Do not use the product in area that is exposed to corrosive gases, chemicals, sea water, water or steam. Otherwise failure or malfunction can result. •Do not use in a place where the product could be splashed by oil or chemicals. If the product is to be used in an environment containing oils or chemicals such as coolant or cleaning solvent, even for a short time, it may be adversely affected (damage, malfunction, or hardening of the lead wires) •Do not use in an area where surges are generated.
  • Page 9 ∗Adjustment and Operation •Turn the power on after connecting a load. Otherwise it can cause excess current causing instantaneous breakage of the product. •Do not short-circuit the load. Although error is displayed when the product load is short circuit, generated excess current lead to cause the damage of the product.
  • Page 10: Model Indication Method

    Model Indication and How to order No.PF##-OMJ0018...
  • Page 11 Option 1 None Power and output lead wire with cable Option 2 None Bracket Panel mount adapter Panel mount adapter + Front protection cover -10- No.PF##-OMJ0018...
  • Page 12 Option 3 None Connector for sensor Part number for options Model No. Option Remarks ZS-28-A Power and output lead wire with cable (2 m) ZS-28-B Bracket M3 x 5 L (2 pcs.) ZS-28-C-1 Connector for sensor 1 pc. ZS-27-C Panel mount adapter M3 x 8 L (2 pcs.) ZS-27-D Panel mount adapter + Front protection cover...
  • Page 13: Names And Functions Of Individual Parts

    Names and Functions of Product Output (OUT1) Display (Green): Light is on when output OUT1 is on. Output (OUT2) Display (Red): Light is on when output OUT2 is on. LCD Display: Displays the current status of flow, setting mode, selected indication unit and error code. Four display modes can be selected: display always in red or green only, or changing from green to red linked to the output.
  • Page 14: Definition And Terminology

    ■Definition and terminology Terminology Definition A type of variable output that has a value proportional to the Analog output measured quantity. When the analog output is in the range of 1 to 5 V or 4 to 20 mA, it will vary continuously, following the change of flow. The total amount of fluid that has passed through the device.
  • Page 15 Terminology Definition The fineness of the set value and display value. Min. setting unit If the minimum setting unit is 1L/min, the flow can be displayed by 1L/min at a time, i.e. 10, 11, 12. Operating temp. range Ambient temperature range in which product is operable. The flow range that can satisfy the specifications indicated in the Rated flow range catalog.
  • Page 16: Mounting And Installation

    Mounting and Installation ■Installation How to mount •Mount the optional bracket and panel mount adapter to the controller. Mounting with bracket •Fix the bracket to the controller with the set screws M3 x 5 L (2 pcs.) attached. •The tightening torque must be 0.5 to 0.7Nm. Mounting with panel mount adapter •Fix the panel mount adapter to the controller with the set screws M3 x 8 L (2 pcs.) as attached.
  • Page 17 Panel thickness: 0.5 to 6 mm Panel cut dimensions Separate Corner: R2 or less Two or more in row n: The number of products Horizontal Vertical Notice when removing the flow monitor The flow monitor with adapter for panel mounting can be removed from facility by making hook of the product wide as illustration after removing two screws.
  • Page 18: Wiring

    ■Wiring Connection •Make connection after turning the power off. •Install the lead wire separately from the route for power cable or high-voltage cable. Otherwise, malfunction may potentially result due to noise. •Be sure to ground Terminal FG when using a switching regulator obtained on the commercial market. If analogue output is performed connecting to a switching regulator obtained on the market, switching noise will be superimposed and product specification can no longer be met.
  • Page 19 Connector Connecting/Disconnecting •When connecting the connector, insert it straight onto the pin holding the lever and connector body between fingers and lock the connector by pushing the lever claw into the square groove in the housing until connector clicks. •When disconnecting the connector, push down the lever by thumb to disengage the lever claw from the square groove.
  • Page 20 Internal circuit and wiring example When the lead wire with SMC power and output lead wire (type ZS-28-A) is used, the colors of wire (Brown, Black, White, Gray, Blue) will apply as shown on circuit diagram. PFM3 0 NPN open collector output: 2 outputs Max.
  • Page 21 PFM3 3 PNP open collector output: 2 outputs Max. 80 mA Residual voltage 1 V or less Analog output: 1 to 5 V Output impedance: Approx. 1 kΩ PFM3 4 PNP open collector output: 2 outputs Max. 80 mA Residual voltage 1 V or less Analog output: 4 to 20 mA Max.
  • Page 22: Flow Setting

    Flow Setting What is measurement mode? The measurement mode is the condition where the flow is detected and indicated, and the switch function is working. This is the basic mode where the setting change and other function settings are available as necessary.
  • Page 23 <How to perform> ∗: The flow monitor will also output during setting. 1. Press the button once in the measurement mode. [LLL] is displayed during measurement mode when the sensor is not connected. 2. [P_1] or [n_1] and set value are displayed by turn. 3.
  • Page 24 4. Press the button to finish the setting of OUT1. [P_2] is displayed to continue with settings for OUT2 as above. Zero clear of indication Indication is reset to zero when are pressed simultaneously for 1 second. For initial use, implementation of zero clear is recommended.
  • Page 25: Function Setting

    Function setting Function selection mode In measurement mode, press the button for 2 seconds or longer to display [F 0]. Display [F ], and point the mode to change the setting of each function. Press the button for 2 seconds or longer at function selection mode to return to measurement mode. ■Setting at the shipment from a factory At the time of shipment, the settings are performed as follows.
  • Page 26 ●[F 2] Operation of OUT2→See page 30 Same setting as [F 1] OUT1. Display color depends on the setting of OUT1. Item Corresponding page Default setting [F 3] Select operating fluid See page 30 Dry air, N [F 4] Display unit selection See page 31 Standard condition (ANR) [F 5] Setting of response time...
  • Page 27: F0 Setting Of Autopreset

    ■[F 0] Unit selection function Be sure to select a sensor to be connected before use. In measurement mode, when the button is pressed for 2 seconds or longer, [F 0] is displayed on the screen. Select Indication unit [Uni] and set value are displayed by turn. Press the button to select the indication unit.
  • Page 28: F1 Operation Of Out1

    ■[F 1] Operation of OUT1 Set output method of OUT1. Output turns on when the flow exceeds the set value. Set value is the medium value of set flow range specified for each product. Display color depends on OUT1 output condition. In the default setting, green lights when output is turned on.
  • Page 29 Flow setting Set flow based on setting procedure on page 28. Hysteresis mode: [P_1] Window comparator mode: [P1L] [P1H] Accumulated output mode: [P1.1] [P1.2] Upper 3 digits are set in [P1.1], lower 3 digits are set in [P1.2]. Accumulated pulse output mode: Omitted ∗: At reversed output, P becomes n.
  • Page 30 ●List of output mode ∗: Operation becomes unstable if hysteresis mode or window comparator mode during unstable condition such as fluid fluctuating. This case, keep interval between set values and start using after confirming stable operation. -29- No.PF##-OMJ0018...
  • Page 31: F2 Operation Of Out2

    ■[F 2] Operation of OUT2 Set output method of OUT2. Display color depends on OUT1 output, and is not set with this function. <Operation> Press the button at function selection mode to display [F 2]. Move on to output mode selection. Press the button.
  • Page 32: F4 Display Unit Selection

    ■[F 4] Display unit selection Standard condition or reference condition is selectable for the display unit. Standard condition (ANR) and reference condition (NOR) are defined as follows: Standard condition: Flow display which is converted in atmospheric pressure at 20 Reference condition: Flow display which is converted in atmospheric pressure at 0 <Operation>...
  • Page 33: F5 Setting Of Response Time

    ■[F 5] Setting of response time Select response time. Output chattering is prevented by setting the response time. <Operation> Press the button at function selection mode to display [F 5]. Move on to setting of response time. Press the button. Setting of response time [rES] and set value are displayed by turn.
  • Page 34: F6 Select Display Mode

    ■[F 6] Select display mode Select instantaneous flow or accumulated flow. <Operation> Press the button at function selection mode to display [F 6]. Move on to select display mode. Press the button. Select display mode [dSP] and set value are displayed by turn. Press the button to select display mode.
  • Page 35: F7 Selection Of External Input

    ■[F 7] External input This function available when external input function is equipped. When the input signal is applied, accumulated value is reset at "0". (Input signal: Connect input like to GND for 30 ms or longer) External reset: When the input signal is applied, accumulated value is reset at "0". Auto-shift: Function to perform output to relative change referring the instantaneous flow when signal is input.
  • Page 36 ●External input-Auto shift, auto shift zero function Auto-shift and auto-shift zero are function to output for relative change amount referring instantaneous flow, when external signal is input, as a base. If auto-shift zero is set, display value is zero when external signal is input.
  • Page 37 •When auto-shift in used Flow sensor ⋅⋅⋅ PFM510, Flow monitor (PFM3) switch set value: n_1=-1.0, H_1=0.4 (Revers output, hysteresis mode) •ON point: (Flow when auto-shift is input)+(n_1) ON/OFF point of this setting ⋅⋅⋅ •OFF point: (Flow when auto-shift is input)+(n_1)+(H_1) -36- No.PF##-OMJ0018...
  • Page 38: F8 Select Display Resolution

    Table below shows the example of the flow display when auto-shift zero is selected. Here, takes normal condition as an example. •Operation example: Flow display before/after auto-shift zero at normal condition Flow display [L/min] ⋅⋅⋅ Before auto-shift 10.0 Input auto-shift at 2.6 ↓...
  • Page 39: F9 Setting Of Auto Preset

    ■[F 9] Set auto preset This function is capable of calculating the specified set value automatically based on the on-going operation. <Operation> Press the button at function selection mode to display [F 9]. Move on to set auto preset. Press the button.
  • Page 40 ●Switch set value during auto preset function mode Auto preset is capable of calculating the specified set value automatically based on the on-going operation. If the button is pressed during measurement mode after auto pre-set function is selected, table below is shown.
  • Page 41: F10 Hold Accumulated Value

    ■[F10] Hold accumulated value Initial setting is to clear accumulated value when the power supply is turned off. It can be set so that the accumulated value is memorized every 2 minutes or 5 minutes. The life of memory element is 1 million times of access. If the flow switch is used 24 hours a day, the life will be, Every 5 minutes to memorize ⋅⋅⋅...
  • Page 42: F11 Select Analog Output Filter

    ■[F11] Select analog output filter This function can be used when analog output function is installed in the products. Faster response signal is available with turning off the filter of the analog output. ∗: If the analog output function is not installed in the products, [---] is indicated and this function is not available. <Operation>...
  • Page 43: F12 Select Power Saving Mode

    ■[F12] Select power saving mode Energy-saving mode is selectable. When the product is left for 30 seconds without any operation, it's shifted to energy-saving mode. It's set in normal mode (energy-saving mode is OFF). (The decimal point blinks during the operation.) <Operation>...
  • Page 44: F13 Set Security Code Input

    ■[F13] Set security code input Pin number can be entered during the key-lock state. See page 47 for key lock function. Code number is not necessary at initial setting. <Operation> Press the button at function selection mode to display [F13]. Move on to set secret code input Press the button...
  • Page 45: F98 Special Function Setting

    Special function setting ● ■ [F98] All function can be set Functions can be set in turn. <Operation> Press the button at function selection mode to display [F98]. Move on to all functions can be set Press the button All functions can be set [ALL] and set value are displayed by turn.
  • Page 46: F99 Reset To The Default Setting

    ∗1: Setting of functions Every time button is pressed, function turns in order below. Set by button. Refer each paragraph for the detail of setting. Function of setting Order Function Applicable model Select connected sensor All models Select indication unit Model with unit change function Select output mode (OUT1) All models...
  • Page 47: Other Setting

    Other settings ●Peak/Bottom value indication The maximum (minimum) flow from when the power is supplied to this moment is detected and updated. In the peak/bottom indication mode, the flow is indicated. As the peak indication, when the button is pressed for 1 second or longer, the maximum flow starts flashing and is held.
  • Page 48 ●Key Lock A wrong operation performed unintentionally such as change of set value can be prevented. If the button operation is performed while key lock setting is being performed, [LoC] is indicated for approx. 1 second. <Operation-Without secret code input-> (1) Keep pressing the button for 5 seconds or longer in the measurement mode.
  • Page 49 •Unlocking (1) Keep pressing the button for 5 seconds or longer in the measurement mode. [LoC] is indicated. (2) Press the button to select unlocking of the key [UnL]. (3) When the button is pressed, the input of security code is asked. For how to input the secret code, refer to [How to input and change the security code] on page 49.
  • Page 50 ●How to change the security code At the time of shipment, the security code is set to [000], but can be changed to optional one. <Operation> (1) After the lock setting is finished (page 47), perform all three steps in the unlock setting procedure. (page 47,(3)).
  • Page 51: Troubleshooting

    Troubleshooting ●Troubleshooting If operation failure happens at a product, please seek a cause of your trouble with the following chart by tracing failure applicable to your case. If the cause you reached seems not to be applicable to your case, and the operates normally after replacing the failed one with a new one, the product would be broken.
  • Page 52 Fault Status Possible cause Item to check Countermeasure An incorrect flow range was Check the selection of the flow Select the appropriate flow selected for the range. range. product to be Wrong connected. Incorrect display display Check if there is air leakage Reconnect the pipes with the because of insufficient Air leakage...
  • Page 53: Error Indication

    ■Error indication function This function is to display error location and content when a problem or an error occurs. Error Name Error Display Error type Troubleshooting Flow exceeds the upper limit of the flow Reduce the flow rate. display range. (1)5% or more flow in the reverse (1)Direct the flow to the Flow error...
  • Page 54: Specification

    Specification ■Specifications Model PFM3 Rated flow range Dry air, N , Ar 0.2 to 10 L/min 0.5 to 25 L/min 1 to 50 L/min 2 to 100 L/min (measurement ∗ 1 range) 0.2 to 5 L/min 0.5 to 12.5 L/min 1 to 25 L/min 2 to 50 L/min Dry air, N...
  • Page 55 Model PFM3 Display unit ±0.5%F.S.±1digit or less 3+1/2 digits 7segment display, 2 color indication (Red/Green) Display Update cycle: 10 times/1 s Indicator light OUT1: ON when light is on (Green), OUT2: ON when light is on (Red) No voltage input (Reed switch or solid state), External input∗...
  • Page 56 Output characteristics ∗: Analog output at maximum rated flow when CO is selected is 3[V] for voltage output type, and 12[mA] for current output type. Rated flow range Max. rated flow 0.2 to 10 L/min 10 (5) L/min 0.5 to 25 L/min 25 (12.5) L/min 1 to 50 L/min 50 (25) L/min...
  • Page 57: Dimensions

    ■Dimensions PFM3□□□ -56- No.PF##-OMJ0018...
  • Page 58 Revision history URL http://www.smcworld.com 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 102-0021 Japan Tel:+81 3 5207 8249 Fax:+81 3 5298 5362 Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. © 2010 SMC Corporation All Rights Reserve No.PF##-OMJ0018...