Model Number Descriptions - Trane Agility HDWA Installation, Operation And Maintenance Manual

Water-cooled chillers with tracer adaptiview control
Table of Contents

Advertisement

Model Number Descriptions

Digit 1, 2 — Unit Function
HD = Agility™ Centrifugal Water-cooled
Chiller
Digit 3 — Drive
W = Direct Drive
Digit 4 — Development Sequence
A
Digit 5, 6, 7 — Nominal Compressor
Tonnage
200= 200 nominal tons
300= 300 nominal tons
400 = 400 Nominal Tons
SSS = Special
Digit 8 — Incoming Line Voltage/Unit
Drive Voltage
B = 208V Incoming Line/460V-60Hz—3Ph
D = 380V Incoming Line/400V-60Hz—3Ph
F = 460V Incoming Line/400V-60Hz—3Ph
G = 480V Incoming Line/400V-60Hz—3Ph
H = 575V Incoming Line/400V-60Hz—3Ph
J = 600V Incoming Line/400V-60Hz—3Ph
R = 380V Incoming Line/400V-50Hz—3Ph
S = Special
T = 400V Incoming Line/400V-50Hz—3Ph
U = 415V Incoming Line/400V-50Hz—3Ph
Digit 9 — Unit Type
A = Cooling Condenser
S = Special
Digit 10, 11 — Design Sequence
AA = Original Design
Digit 12 — Manufacturing Location
L = La Crosse, Wisconsin
Digit 13 — Hot Gas Bypass
0 = Without HGB
S = Special
Digit 14 — Control Enclosure
C = Standard Control Enclosure
D = Standard Control Enclosure with Tracer®
SC
S = Special
Digit 15 — Evaporator Shell Size
A= 020A Evaporator Shell
C = 040A Evaporator Shell
S = Special
8
Digit 16 — Evaporator Tube Bundle
A = Evaporator Tube Bundle A
B = Evaporator Tube Bundle B
C = Evaporator Tube Bundle C
D = Evaporator Tube Bundle D
E = Evaporator Tube Bundle E
S = Special
Digit 17 — Evaporator Tubes
C = 0.025 Wall Thickness—0.75 Diameter
Internally Enhanced Copper Evaporator Tube
M = 0.025 Wall Thickness—0.75 Diameter
High Performance Internal Surface
Evaporator Tube
S = Special
Digit 18 — Evaporator Waterbox
B= 150 marine — 2 pass
F = 150 psi Non-marine, 2-Pass Standard
S = Special
Digit 19 — Condenser Shell Size
A = 020A Condenser Shell
C = 040A Condenser Shell
S = Special
Digit 20 — Condenser Tube Bundle
A = Condenser Tube Bundle A
B = Condenser Tube Bundle B
C = Condenser Tube Bundle C
S = Special
Digit 21 — Condenser Tubes
C = 0.025 Condenser Tube Wall— 0.75
Internal Enhanced Copper Tube
J = 0.028 Condenser Tube Wall—0.75
Internal Enhanced Copper Tube
S = Special
Digit 22 — Condenser Waterbox
B = 150 PDI marine — 2 pass
F = 150 psi Non-marine, 2-Pass Standard
S = Special
Digit 23 — Evaporator Expansion
Valve
A = 400
B = 200
S = Special
Digit 24 — Unit Option
B = Insulation Package and Spring Loaded
Pressure Relief Valve
D = Spring Loaded Pressure Relief Valve Only
Digit 25 — Control: Generic Building
Automation System (BAS)
0 = None
G = Generic BAS
Digit 26 — Control: Extended
Operation
0 = None
1 = Extended Operation
Digit 27 — Tracer® ® Communication
Interface
0 = None
2 = Tracer® Comm 5
3 = Tracer® MODBUS®
4 = Tracer® BACnet®
Digit 28 — Special Options
0 = None
S = Special Option
Digit 29 — Control: Water Flow
Control
0 = None
W = Water Flow Control
Digit 30 — Control: Chilled Water
Reset
0 = None
1 = Chilled Water Reset
Digit 31 — Control: Operating Status
0 = None
1 = Operating Status
Digit 32 — Industrial Chiller Package
(INDP)
0 = Without INDP
Digit 33 — Control Power Transformer
(CPTR)
0 = Without CPTR
S = Special
Digit 34 — Thermal Dispersion Water
Flow Proving
0 = None, Customer to Provide Device for
Condenser and Evaporator
A = Thermal Dispersion Water Flow Proving
Selected for Condenser and Evaporator
HDWA-SVX001D-EN