12.3.1.2 Removing the dummy cover bay 2

If bay 2 is to be equipped, it is necessary to remove its dummy cover and metal
bay cover.
V
CAUTION!
You cannot install the metal bay cover again.
Only remove metal bay cover before installing RDX drive to comply with
applicable EMC regulations and satisfy cooling requirements.
Ê Remove the front cover, see section
Figure 95: Removing the dummy cover bay 2
Ê Push the dummy cover out of bay 2 from the rear side of the front cover.
Figure 96: Fastening points on the metal bay cover in bay 2
Ê Cut the three fastening points on the metal bay cover by using diagonal
pliers.
Ê Remove the metal bay cover.
164
Upgrade and Maintenance Manual
"Removing the front cover" on page
50.
TX1310 M3