2. General
Projector
DP2K-P
DP4K-19B
DP4K-23B
The power cord required to connect the projector with the power net is not delivered with the projector. It is the responsibility of the
customer to provide the correct type of power cord. The cross-sectional area of the conductors in the power supply cord shall not
be less than 4 mm² or 10 AWG, minimum 300V.
To protect operating personnel, the National Electrical Manufacturers Association (NEMA) recommends that the instrument panel
and cabinet be grounded. In no event shall this projector be operated without an adequate cabinet ground connection.
The AC supply must be installed by a qualified electrician in conformance to local codes. Hardware, wire sizes and conduit types
must comply with local codes.
A readily accessible disconnect device shall be incorporated externally to the equipment for removal of the power to the equipment
mains terminals.
The building installation must be provided with a circuit breaker of max. 40A to protect the complete unit.
W
ARNING
of all power from the unit
UPS requirements
The Uninterruptible Power Supply (UPS), also known as a Continuous Power Supply (CPS), must have an output voltage of 200-
240V at 50-60Hz and must be capable of delivering an output current of 5,5 amperes.
The connection between the UPS unit and the UPS inlet of the projector must be done with a certified AC power supply cord of
minimum 0,75 mm² or 18 AWG and minimum 300V.
C
AUTION
unit with power! The UPS OUTLET of the projector may only be used for connection to the UPS INLET of the
projector.
The B-series projector does not have a built in UPS unit.
Exhaust outlet for external fan
The exhaust outlet has an output voltage of 200–240V at 50–60 Hz; switched and maximum 3 amperes is allowed.
The connection between the exhaust outlet and the external blower must be done with a certified AC power supply cord of minimum
0,75 mm² or 18 AWG and minimum 300V.
C
AUTION
any other device than an external exhaust fan. Maximum allowed current : 3A.
Projector weight
Do not underestimate the weight of the B-series projector. The projector weights about ±133 kg (±293 lb.) without lens. Be sure that
the pedestal on which the projector has to be installed is capable of handling five (5) times the complete load of the system.
Barco offers a pedestal for the B-series projector. This universal pedestal allows a solid and easy setup of the
projector. The universal pedestal has a separate compartment to install the UPS unit for the B-series projector.
Futhermore, the universal pedestal contains a standard 19" rack to build in the projector peripherals such as
alternative content switchers (e.g. ACS-2048)
10
Power requirements
200-240 VAC, 50-60Hz, 30A at 200 VAC
200-240 VAC, 50-60Hz, 24A at 200 VAC
200-240 VAC, 50-60Hz, 30A at 200 VAC
:
Disconnect the power to the unit mains terminals and unplug power cord at UPS inlet for removal
:
The 200–240V power outlet (UPS OUTLET) of the projector may not be used to provide the UPS
:
The 200–240V power outlet (exhaust outlet) of the projector may not be used to provide power to
R5905067 DPXK-19B/23B/P 17/09/2012