Tab. 1/d
LOGIC "P"
AUTOMATED SYSTEM
STATUS
CLOSED
OPENING
no effect
no effect
OPEN
(closing disabled)
reverses immediately
CLOSING
at opening
STOPPED
Tab. 1/e
LOGIC "PA"
AUTOMATED SYSTEM
STATUS
opens and closes after
CLOSED
pause time
OPENING
no effect
OPEN IN PAUSE
recharges pause time
reverses immediately
CLOSING
at opening
opens and closes after
STOPPED
pause time
Tab. 1/f
LOGIC "Cn"
AUTOMATED SYSTEM
STATUS
CLOSED
OPENING
no effect
no effect
OPEN
(closing disabled)
reverses immediately
CLOSING
at opening
STOPPED
In brackets: effects on the other inputs when pulse active
OPEN A
CLOSE
opens
no effect
closes immediately
at end of opening
closes
no effect
opens
closes
OPEN A
CLOSE
no effect
closes immediately
at end of opening
closes
no effect
closes
OPEN A
CLOSE
opens
no effect
closes immediately
at end of opening
closes
no effect
opens
closes
PULSES
STOP
FSW
no effect
no effect
(opening disabled)
stops operation
no effect
no effect
no effect
(closing disabled)
(closing disabled)
stops and continues
stops operation
to close on release
no effect
no effect
(opening and
(closing disabled)
closing disabled)
PULSES
STOP
FSW
no effect
no effect
(opening disabled)
stops operation
no effect
recharges pause
time
stops operation
(closing disabled)
stops and continues
stops operation
to close on release
no effect
no effect
(opening and
(closing disabled)
closing disabled)
PULSES
STOP
FSW
no effect
no effect
(opening disabled)
stops operation
no effect
no effect
no effect
(closing disabled)
(closing disabled)
reverses
stops operation
immediately at
opening
no effect
no effect
(opening and
closing disabled)
(closing disabled)
3
LOOP 1
LOOP 2
opens and at end
of opening closes if
no effect
disengaged
closes immediately
no effect
at end of opening
no effect
closes
reverses immediately
at opening and closes
stops and continues
at end of opening if
to close on release
disengaged
opens and at end
no effect
of opening closes if
(closing disabled)
disengaged
LOOP 1
LOOP 2
opens and at end
of opening closes if
no effect
disengaged
closes immediately
no effect
at end of opening
recharges pause time
closes
reverses immediately
at opening and closes
stops and continues
at end of opening if
to close on release
disengaged
opens and at end
no effect
of opening closes if
(closing disabled)
disengaged
LOOP 1
LOOP 2
opens
no effect
closes immediately
no effect
at end of opening
no effect
closes
reverses
reverses immediately
immediately at
at opening
opening
no effect
opens
(closing disabled)