Tab. 1/a
LOGIC "A"
AUTOMATED SYSTEM
STATUS
opens and closes after
CLOSED
pause time
OPENING
no effect
OPEN IN PAUSE
recharges pause time
reverses immediately
CLOSING
at opening
STOPPED
Tab. 1/b
LOGIC "A1"
AUTOMATED SYSTEM
STATUS
opens and closes after
CLOSED
pause time
OPENING
no effect
OPEN IN PAUSE
recharges pause time
reverses immediately
CLOSING
at opening
STOPPED
Tab. 1/c
LOGIC "E"
AUTOMATED SYSTEM
STATUS
CLOSED
OPENING
stops operation
OPEN
reverses immediately
CLOSING
at opening
STOPPED
In brackets: effects on the other inputs when pulse active
OPEN A
CLOSE
no effect
reverses
immediately at
closing
closes
no effect
closes
closes
OPEN A
CLOSE
no effect
reverses
immediately at
closing
closes
no effect
closes
closes
OPEN A
CLOSE
opens
no effect
reverses
immediately at
closing
closes
closes
no effect
closes
closes
PULSES
STOP
FSW
no effect
(opening disabled)
no effect
stops operation
no effect
recharges pause
time
stops operation
(closing disabled)
reverses
stops operation
immediately at
opening
no effect
no effect
(opening and
(closing disabled)
closing disabled)
PULSES
STOP
FSW
no effect
no effect
(opening disabled)
closes immediately
stops operation
at end of opening
stops operation
closes
reverses
stops operation
immediately at
opening
no effect
no effect
(opening and
(closing disabled)
closing disabled)
PULSES
STOP
FSW
no effect
no effect
(opening disabled)
stops operation
no effect
no effect
no effect
(closing disabled)
(closing disabled)
reverses
stops operation
immediately at
opening
no effect
no effect
(opening and
(closing disabled)
closing disabled)

LOOP 1
LOOP 2
opens and closes after
no effect
pause time
no effect
no effect
recharges pause
time
recharges pause time
(closing disabled)
reverses
reverses immediately
immediately at
at opening
opening
no effect
opens and closes after
pause time
(closing disabled)
LOOP 1
LOOP 2
opens and closes after
no effect
pause time
closes immediately
no effect
at end of opening
recharges pause time
closes
reverses
immediately at
reverses immediately
opening, closes
at opening
when opening
finished
no effect
opens and closes after
pause time
(closing disabled)
LOOP 1
LOOP 2
opens
no effect
no effect
no effect
no effect
closes
(closing disabled)
reverses
reverses immediately
immediately at
at opening
opening
no effect
opens
(closing disabled)

Hide quick links: