J1.Terminal-Board.-.Accessories.(Fig.2); J2.Terminal-Board; J8.Connector.-.Motor.capacitor.(Fig.2); J9.Terminal-Board.-.Power.supply.(Fig.2) - FAAC 624BLD Manual

Hide thumbs Also See for 624BLD:
Table of Contents

Advertisement

Connection of one safety device
1
2
3
4
5
6
7
8
J1
Connection of no device with NC contact
1
2
3
4
5
6
7
8
J1

.......4.2....J1.TERMINAL-BOARD.-.ACCESSORIES.(FIG.2)

LOOP 1 - Power supply to loop1 (OPEN - terminals 1-2): use these
terminals to connect the loop you wish to use as an OPEN pulse
generator.
LOOP 2 - Power supply to loop2 (SAFETY/CLOSE - terminals 3-4):
connect between these terminals the loop you wish to use as a
SAFETY/CLOSE pulse generator.
OPEN - "Opening" Command (N.O. - terminal 5): this refers to any
pulse generator (e.g.: push-button) which, by closing a contact,
commands the barrier to open and/or close.
To install several total opening pulse generators,
connect the N.O. contacts in parallel (see fig. 4).
CLOSE - "Closing" Command (N.O. - terminal 6): this refers to any
pulse generator (e.g.: push-button) which, by closing a contact,
commands the barrier to close.
To install several total opening pulse generators,
connect the N.O. contacts in parallel (see fig. 4).
FSW - Closing safety-devices contact (N.C. - terminal 7) The purpose
of the closing safety devices is to protect the barrier movement
area during closure, by reversing motion. They are never tripped
during the opening cycle. If the closing safety devices are
engaged when the automated system is in open status, they
prevent the closing movement.
To install several closing safety devices, connect the
N.C. contacts in series (fig. 3).
If.closing.safety.devices.are.not.connected,.jumper.
connect.the.FSW.and.OUT1.terminals.(fig..8).
STOP - STOP contact (N.C. - terminal 8): this refers to any device
(e.g.: push-button ) which, by opening a contact, can stop the
motion of the automated system.
To install several STOP devices, connect the N.C.
contacts in series (fig. 3).
If.stop.safety.devices.are.not.connected,.jumper.
connect.the.STOP.and.GND.terminals.(fig..8).
EMERGENCY - EMERGENCY contact (N.C. - terminal 9) this refers to
any switch which, by being activated in emergency state, opens
the barrier and stops its movement until the contact is restored.
If.emergency.safety.devices.are.not.connected,.
jumper. connect. the. EMERGENCY. and. GND.
terminals.(fig..8).
9
10 11
12 13
14
15
16 17
18
Fig. 7
9
10 11
12 13
14
15
16 17
18
Fig. 8
GND
(teminals 10-11-19) - Negative contact for feeding
accessories
24 Vdc (terminals 12-13) - Positive contact for feeding
accessories
. Max.. load. of. accessories:. 500. mA.. To. calculate.
19
absorption. values,. refer. to. the. instructions. for.
individual.accessories.
OUT 1 - Outout 1 (terminal 14):The output can be set in one of the
functions described in nd level programming (see par.5..).
Default value is FAILSAFE.
Maximum applicable load: 4 Vdc with 00 mA.
OUT 2 - Output 2 (terminal 15): The output can be set in one of the
functions described in nd level programming (see par.5..).
Default value is CLOSED beam.
Maximum applicable load: 4 Vdc with 00 mA.
19
OUT 3 - Output 3 (terminal 16-17): The output can be set in one of
the functions described in nd level programming (see par.5..).
Default value is INDICATOR LIGHT.
Connect a 4 Vdc - 3 W max. indicator light, if any, to these
terminals, following the instructions in fig. .
Maximum applicable load: 4 Vdc or Vac with 500 mA.
.
.To. avoid. endangering. correct. operation. of. the.
system,.do.not.exceed.the.indicated.power.
OUT 4 - Output 4 (terminal 18): The output can be set in one of
the functions described in nd level programming (see par.5..).
Default value is BEAM LIGHTING.
Maximum applicable load: 4 Vdc with 00 mA.
4.3..J2.TERMINAL-BOARD.-..MOTOR.-.FLASHING.LIGHT.AND.
FAN.(FIG.2)
M (COM-MOT1-MOT2): Motor connection
LAMP (LAMP-COM): Flashing light output ( 30 V ~)
FAN (FAN-COM): Fan output ( 30 V ~)
4.4..

J8.CONNECTOR.-.MOTOR.CAPACITOR.(FIG.2)

Rapid connector for connecting the motor thrust capacitor.
4.5..

J9.TERMINAL-BOARD.-.POWER.SUPPLY.(FIG.2)

PE :
Earth connection
N :
Power supply 30 V~ ( Neutral )
L
:
Power supply 30 V~ ( Line )
.
. To.ensure.correct.operation,.the.board.must.be.
connected.to.the.earth.conductor.in.the.system..
Install.an.adequate.differential.thermal.breaker.
upstream.of.the.system.
4.6..
J3,. J5. RAPID. CONNECTORS. -. FOR. OPENING. AND.
CLOSING.LIMIT-SWITCHES.(FIG.2)
Quick-fit connector for connection of the opening (J3) and closing (J5)
limit-switches.
5