5.5.. MODIFICATION.OF.PRE-SETTING.OF.LOGICAL.PARAMETERS.

dF
The modification of
parameter enables to automatically load 4
different configurations modifying all programming values on every
level with preset values.
This possibility is a starting point for subsequent 'fine tuning' of other
parameters depending on the application and its context.
01
For example, if you choose
and exiting from st level programming,
all the FAAC default values which can be found in tables of st, nd and
3rd level in the "Default" column are loaded.
In this way, all the parameters in the memory are returned to a known
standard condition (see table under).
To implement the loading of the values of one of the 4 pre-settings,
select the required number and exit st level programming.
If you do not wish to load or modify a pre-setting, leave the
00
on value
.
The table below shows the main default values which are loaded on
selecting each of the 4 pre-settings:
d F =0 1 d F =02 d F =03 d F =04
Parameters
Lo
logic
PA
pause
OF
force
L 1
loop 
L2
loop 
S 1
not used
S2
not used
bo
boost
PF
pre-flashing
SC
slow closing
tr
slow-down
t
time out
FS
fail safe
o 1
output 
P 1
polarity 
o2
output 
P2
polarity 
o3
output 3
P3
polarity 3
o4
output 4
P4
polarity 4
A5
assistance
nc
cycles .
nC
cycles .
h 1
not used
h2
not used
25
26
27
A 1
A2
A3
A4
A5
A6
A7
A8
A9
b 1
b2
dF
E
A 1
rb
rb
20
30
30
50
no
no
5
5
Y
no
CL
no
3
20
12
12
no
00
16
15
15
no
03
17
14
14
no
0 1
0 1
no
02
no
no
00
0 1
no
no
no
no
no
5
4
no
no
4
4
no
Y
no
no
no
no
Y
no
30
Attention:.The.selection.of.a.default.and.subsequent.exit.
from.1st.level.programming.entails.the.deletion.of.all.the.
modifications.made.previously.
Make. sure. that. you. carry. out. the. required. default. .
loading.and.exit.1st.level.programming.BEFORE.modifying.
other.steps.
6..

START-UP

6.1.. LEDS.CHECK

The following table shows the status of the LEDs in relation to the status
of the inputs (the closed at rest automated system condition is shown
in bold).
Check the status of the signalling LEDs as per table below:
step
Note that:
Operation of status signalling LEDs
LED
Description
DL
OPEN
DL
CLOSE
DL3
FSW
DL4
STOP
DL5
EMERGENCY
DL6
FCA
DL7
FCC
DL8
PIVOT
7..

AUTOMATED.SYSTEM.TEST

When you have finished programming, check if the system is operating
correctly.
Above all, check if power is adequately adjusted and if the safety
devices operate correctly.
4
Y
Y
Y
0
L
= closed contact
ed
on
L
= open contact
ed
off
ON (closed contact)
OFF (Open contact)
Command enabled
Command disabled
Command enabled
Command disabled
Safety devices released
Safety devices engaged
Command disabled
Command enabled
Command disabled
Command enabled
Opening limit switch free
Opening limit switch engaged
Closing limit switch free
Closing limit switch engaged
Beam attached
Beam detached
Fig. 10