How the Various Functions Are Used
7.1
Switching Screens
Using the auto - paging function
The GT main unit has an "Auto - paging" function that automatically switches the screen
to a specified screen number when a certain period of time has elapsed. This function
can be used to switch screens automatically.
For information on setting the auto - paging function, please see page 87 (GT10)
and page 116 (GT30).
If using this function, please be aware that the value of the third word in the basic
communication area / word device (the number of the currently displayed screen)
changes to that of the new screen number, but the contents of the first word (the screen
number specified by the PLC) do not change. For detailed information, see page 139.
Clicking on the
the number of the screen to which the display is to be changed.
Value Set dialog box
138
button displays the value setting dialog box shown below. Specify
If the value is entered with the
button pressed as shown at the left, a
hexadecimal screen number is speci-
fied, and if the value is entered with
the
button pressed, a decimal
value is entered.
The
button acts as a backspace
key when entering an address, and the
button functions as a Clear key.