GT30 Configuration Settings
6.2
Entering Configuration Settings from GTWIN Screen Creation Tool
GT internal device hold
"GT Internal Device Hold" is a function that backs up the values for an internal device
(GWR or GDT) in the GT main unit.
Data register
Don't hold - - - The GT internal device hold function is turned off.
Hold - - - The GT internal device hold function is turned on.
Internal relay
Don't hold - - - The GT internal device hold function is turned off.
Hold - - - The GT internal device hold function is turned on.
If the above setting for the GT internal device hold function is set to "Hold", a "Start No."
item is displayed. Click on the
below, and specify a starting number. After the setting has been entered, the contents
of any addresses subsequent to the specified value will be held.
Value setting dialog box
Key points
GT internal devices
Device type
Data register
Memory
Memory
Internal relay
Bits
Internal relay
* The WGR and GR are the same memory, but in the WGR, bits are handled in word units.
124
button to display the value setting dialog box shown
Enter the starting number, using the ten - key pad.
The
button functions as a backspace key when
entering addresses.
The
button acts as a Clear key.
Address range
GDT0000 to GDT2047
WGR0000 to WGR0255
GR0000 to GR255F
GT10/GT30
Points
2048 words
256 words
4096 points