Sample Setup: Cold Plate With External Liquid Heat Sink - Siemens SINAMICS S120 Equipment Manual

Booksize power sections cold plate
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Cold plate with external air heat sinks
2.3 Example: cold plate with external liquid heat sink
2.3.2

Sample setup: cold plate with external liquid heat sink

Active Line Module
Figure 2-4
Example: cold plate drive line-up with external liquid cooling
Setup:
• Supply: Active line module 55 kW
• 7 single motor modules
• 3 internal fans at the top of the cabinet
• A joint external liquid heat sink (1200 mm x 480 mm)
The heat sinks and fans are not part of the scope of supply.
Recommended suppliers of liquid heat sinks include:
DAU Ges.m.b.H. & CO.KG, Ligist:
2-6
55 kW
Control cabinet internal fan
External fluid heat sinki 1200 mm
Single Motor Modules
85 A, 60 A, 30 A, 60 A, 18 A, 18 A, 18 A
Control cabinet 1730 mm
http://www.dau-at.com
Equipment Manual Booksize Cold-Plate Power Sections
Manual, (GH4), Edition 06.2005, 6SL3097-2AJ00-0BP2

Advertisement

Table of Contents
loading