X22 Terminals: Smart Line Module; X24 24 V Terminal Adapter - Siemens SINAMICS S120 Equipment Manual

Booksize power sections cold plate
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

6.3.5

X22 terminals: smart line module

Table 6-3
Terminal block X22
Terminal
1
2
3
4
Max. connectable cross-section: 1.5 mm
Type: Screw terminal 1 (see Connection Methods)
6.3.6

X24 24 V terminal adapter

Table 6-4
Terminal block X24
Terminal
+
M (GND)
The 24 V terminal adapter is supplied as standard
Max. connectable cross-section: 6 mm
Equipment Manual Booksize Cold-Plate Power Sections
Manual, (GH4), Edition 06.2005, 6SL3097-2AJ00-0BP2
Name
24 V power supply
DI: Disable Regeneration
DI: Reset
Ground
2
Designation
24 V power supply
Ground
2
Smart Line Modules (5 kW and 10 kW) with cold plate
Technical specifications
Electronics power supply for controlling digital inputs
X22.2 and 3.
Deactivate feedback
No power is supplied back to the network from the DC
link. The regenerative energy of the motors may have
to be reduced using a combination of the Braking
Module and braking resistor.
Reset faults (positive edge)
Electronic ground
Technical specifications
24 V DC supply voltage
Electronic ground
6.3 Interface description
6-7

Advertisement

Table of Contents
loading