VERITAS 5150 Product Description Manual

Hide thumbs Also See for 5150:

Advertisement

Quick Links

Veritas 5150 Appliance
Product Description Guide

Advertisement

Table of Contents
loading

Summary of Contents for VERITAS 5150

  • Page 1 Veritas 5150 Appliance Product Description Guide...
  • Page 2 Technologies LLC or its affiliates in the U.S. and other countries. Other names may be trademarks of their respective owners. This product may contain third-party software for which Veritas is required to provide attribution to the third party (“Third-party Programs”). Some of the Third-party Programs are available under open source or free software licenses.
  • Page 3 Japan CustomerCare_Japan@veritas.com Documentation Make sure that you have the current version of the documentation. Each document displays the date of the last update on page 2. The latest documentation is available on the Veritas website: https://www.veritas.com/content/support/en_US/dpp.Appliances.html Documentation feedback Your feedback is important to us. Suggest improvements or report errors or omissions to the documentation.
  • Page 4: Table Of Contents

    Chapter 1 About the Veritas 5150 Appliance ........6 About the appliance ................ 6 Features and components of the Veritas 5150 Appliance ......7 Locating the appliance serial number ..........8 Appliance disk drives ..............9 Appliance control panel ..............9 About the Power button LED states ..........
  • Page 5 Contents Product safety compliance ............. 33 Product EMC Compliance - Class A Compliance ........ 33 Product ecology compliance ............33 Electromagnetic compatibility notices ..........34 FCC Verification Statement (USA) ........... 34 ICES-003 (Canada) ..............35 CE Declaration of Conformity (Europe) ..........35 VCCI (Japan) ................
  • Page 6: About The Veritas 5150 Appliance

    ■ Appliance I/O configuration options ■ About the appliance The Veritas 5150 Appliance is a hardware and software storage system that can scale to 14 TB of usable capacity. Veritas 5150 Appliance Figure 1-1 The Veritas 5150 Appliance supports the following software: Flex version 1.3 and...
  • Page 7: Features And Components Of The Veritas 5150 Appliance

    About the Veritas 5150 Appliance Features and components of the Veritas 5150 Appliance Refer to the Veritas 5150 documentation at the following site for details about usable storage options. Appliance Documentation Features and components of the Veritas 5150 Appliance This section describes the features and components of the Veritas 5150 Appliance.
  • Page 8: Locating The Appliance Serial Number

    About the Veritas 5150 Appliance Locating the appliance serial number Veritas 5150 Appliance features (continued) Table 1-1 Feature Description RAID levels RAID 1 (standard mirroring) and RAID 10 (block level striping with double distributed parity) are implemented as follows: Appliance system disks: RAID 1 ■...
  • Page 9: Appliance Disk Drives

    SATA SSD 32GB Appliance control panel The front panel of the Veritas 5150 Appliance includes a small panel that is attached to the right side of the device. The panel provides basic control of the system as well as LED status indicators such as the power button, ID button/LED, and system...
  • Page 10 About the Veritas 5150 Appliance Appliance control panel Control panel system Figure 1-3 Control panel system LED descriptions Table 1-3 System information Power button with integrated The Power button toggles the system on and off. “About the Power button LED states”...
  • Page 11: About The Power Button Led States

    16. About the Power button LED states The Power button is located on the Veritas 5150 Appliance control panel. It is used to turn the appliance on and off. The following table provides a description of each power state.
  • Page 12: About The System Status Led States

    About the Veritas 5150 Appliance Appliance control panel Power button LED states Table 1-4 State Power Mode Description Power - off Non-ACPI The system power is off, and the BIOS has not initialized the chipset. Power - on Non-ACPI The system power is on and the green Power button LED is active.
  • Page 13 About the Veritas 5150 Appliance Appliance control panel System Status LED states (continued) Table 1-5 Color State Criticality Description Green ~1-Hz blinking Degraded System degraded: The system is Redundant loss, such as power supply or ■ operating in a fan. Applies only if the associated platform degraded state sub-system has redundancy capabilities.
  • Page 14 About the Veritas 5150 Appliance Appliance control panel System Status LED states (continued) Table 1-5 Color State Criticality Description Green ~1-Hz blinking Degraded System degraded: (continued) The system is In mirrored configuration, when memory ■ operating in a mirroring takes place and system loses degraded state memory redundancy.
  • Page 15: About The Drive Carrier Led States

    About the Veritas 5150 Appliance Appliance control panel System Status LED states (continued) Table 1-5 Color State Criticality Description Amber Solid on Critical, Fatal alarm – system has failed or shutdown: non-recoverable CPU CATERR signal asserted ■ – System is MSID mismatch detected (CATERR also ■...
  • Page 16: About The Power Supply Led States

    About the Veritas 5150 Appliance Appliance control panel Amber LED status Table 1-6 LED state Drive status Solid On (SO) Hard drive fault No access and no fault 1-Hz blinking RAID rebuild in progress 2-Hz blinking Locate (identify) Green LED status...
  • Page 17: Appliance Rear Panel

    Appliance rear panel The rear panel of the appliance contains several default ports that are embedded. Rear panel Figure 1-4 The following list describes the numbered ports. VGA port 3 USB ports Veritas Remote Management Interface (remote management (IPMI) port)
  • Page 18: Appliance Front Panel Usb Port

    5 Gb/second. Veritas 5150 Appliance front USB port Figure 1-5 Appliance I/O configuration options The Veritas 5150 Appliance has one functional PCIe slot, with three PCIe card options: 2 x 10 GbT ■...
  • Page 19: Intel I350-T4 Quad-Port 1Gb Ethernet Card

    LED indicators LINK (solid) and ACTIVITY (blinking) LINK SPEED (green=10Gbps; yellow=1Gbps) Air Flow (minimum) 200 LFM (linear feet per minute) Intel I350-T4 Quad-port 1Gb Ethernet card The Intel I350-T4 adds 4 extra 1Gb RJ45 connections to the Veritas 5150 Appliance.
  • Page 20 About the Veritas 5150 Appliance Appliance I/O configuration options Quad-port 1Gb Ethernet card with RJ45 connectors specifications Table 1-11 Item Specification Bracket height Full Height Power consumption Typical: 5 watts @ 1Gbps Maximum: 6 watts @ 1Gbps Operating temperature 0°C to 55°C (32 F to 131 F) Storage temperature -40°C to +70°C (-40°F to +158°F)
  • Page 21: Mellanox Connectx -4 Lx En Mcx4121A-Acat Ethernet Card

    About the Veritas 5150 Appliance Appliance I/O configuration options Quad-port 1Gb Ethernet card with RJ45 connectors specifications Table 1-11 (continued) Item Specification LED indicators LINK GREEN (solid) and ACTIVITY (blinking) LINK SPEED (green=100Mbps; yellow=1Gbps; off=10Mbps) Air Flow (minimum) 0 LFM (linear feet per minute)
  • Page 22: Sas Tape-Out Adapter

    Air Flow (minimum) 300 LFM (linear feet per minute) SAS tape-out adapter The SAS tape-out adapter is used to connect external SAS devices to the Veritas 5150 Appliance. The adapter comes standard on all configurations of Veritas 5150 Appliance. The SAS tape-out adapter assembly includes a port for external SAS-3 device connections and an attached internal SAS-3 cable.
  • Page 23: Veritas 5150 Appliance Cables

    ■ Power cables Each of the AC power modules in the Veritas 5150 Appliance accepts one AC power cable. One end of the AC power cable is connected to the power supply on the appliance. The other end of the cable is connected to an external Power Distribution Unit (PDU) on the rack.
  • Page 24: Ac Power Cable With The Iec-60320-C14 Plug

    Veritas 5150 Appliance cables Power cables AC power cable with the IEC-60320-C14 plug IEC-60320-C14 plug Figure 2-1 AC power connector (IEC-60320-C14) to an external power supply Power Distribution Unit (PDU) on a rack. AC power connector (IEC-60320-C13) to the appliance.
  • Page 25: Network Cable

    26. Multi-mode fiber optic cable The Veritas 5150 Appliance communicates with the Fibre Channel switch through a multi-mode fiber optic cable. One end of the multi-mode fiber optic cable connects to the 10GbE service network port. The other end of the cable connects to the Fibre...
  • Page 26: Twinaxial Copper Cables

    26. Twinaxial copper cables The Veritas 5150 Appliance communicates with Ethernet networks through high speed Twinaxial copper cables. If you configure the appliance to communicate with 10 Gb Ethernet networks, these cables connect to the 10/25 Ethernet card in the...
  • Page 27 Veritas 5150 Appliance cables Twinaxial copper cables These cables are also known as Direct Attach copper cables (DAC), and are available in 1-meter, 3-meter, or 5-meter lengths.
  • Page 28: Technical Specifications And Compliance Standards

    Electromagnetic compatibility notices ■ FCC Verification Statement (USA) ■ ICES-003 (Canada) ■ CE Declaration of Conformity (Europe) ■ VCCI (Japan) ■ BSMI (Taiwan) ■ Veritas 5150 Appliance technical specifications The following table provides technical specifications for the Veritas 5150 Appliance.
  • Page 29 Veritas 5150 Appliance Rack information 19" EIA standard The rack rails that are provided for the Veritas 5150 Appliance are extensible to 36” (914mm). This distance is the maximum depth that is allowed between rack posts. If the distance between rack posts is longer than 36” (914mm) the rails and the appliance cannot be properly installed.
  • Page 30: Environmental Specifications

    Power conversion efficiency 90% + Acoustic noise 70 dBA “Environmental specifications” on page 30. Environmental specifications The following table lists the environmental specifications for the Veritas 5150 Appliance. Veritas 5150 Appliance environmental specifications Table A-2 Specification Veritas 5150 Appliance Operating temperature ASHRAE A2 - from 10°C to 35°C with the maximum rate of...
  • Page 31: Protocol Standards

    10°C/hour (50°F/hour) “ Veritas 5150 Appliance technical specifications” on page 28. “Protocol standards” on page 31. Protocol standards The following table provides standards with which the Veritas 5150 Appliance complies. Veritas 5150 Appliance compliance Table A-3 Standard Version IPMI 2.0 Intelligent Platform Management Interface Specification Second Generation v2.0, Document Revision 1.0...
  • Page 32: Regulatory, Compliance, And Certification Information

    Technical specifications and compliance standards Regulatory, compliance, and certification information “Environmental specifications” on page 30. Regulatory, compliance, and certification information The following sections give information about the product regulations and compliance. WARNING To ensure regulatory compliance, you must adhere to the assembly instructions in this guide to ensure and maintain compliance with existing product certifications and approvals.
  • Page 33: Product Safety Compliance

    Technical specifications and compliance standards Product safety compliance Product safety compliance The following is a list of product safety compliance norms for different countries: UL60950 - CSA 60950 (USA / Canada) ■ EN60950 (Europe) ■ CB Certificate & Report, IEC60950 (report to include all country national ■...
  • Page 34: Electromagnetic Compatibility Notices

    Technical specifications and compliance standards Electromagnetic compatibility notices Quantity limit of 0.01% by mass (100 PPM) for: Cadmium ■ California Code of Regulations, Title 22, Division 4.5, Chapter 33: Best ■ Management Practices for Perchlorate Materials China - Restriction of Hazardous Substances (China RoHS) ■...
  • Page 35: Ices-003 (Canada)

    Technical specifications and compliance standards ICES-003 (Canada) is likely to result in interference to radio and TV reception. All cables that are used to connect to peripherals must be shielded and grounded. Operation with regulatory and compliance information 65 Electromagnetic compatibility notices the cables that are connected to peripherals that are not shielded and grounded may result in interference to radio and TV reception.
  • Page 36: Index

    9 environmental specifications 30 processor type 7 features protocol standards processor 7 Veritas 5150 Appliance 31 RAID levels 7 system memory configuration (DIMMS) 7 front panel RAID levels 7 USB port 18 front panel USB port 18...

Table of Contents