Download Print this page

VERITAS 5150 Manual

Hardware service procedure

Advertisement

Quick Links

Veritas Appliance
Hardware Service Procedure
Replacing a power supply: Veritas 5150 Appliance
Document Number: 298
Version: 1.0 (01-Dec-2019)
Purpose
This document describes the process for replacing a power supply in a Veritas appliance.
Affected Models
The instructions that are provided in this document pertain to the following Veritas appliance hardware:
5150 Appliance
Electrical Safety
The static discharged by human bodies can damage static-sensitive components on the boards.
When installing and maintaining the equipment, observe appropriate electrostatic safety precautions
to prevent personnel injuries or device damage.
When operating a device in an electrostatic sensitive area, you must take electrostatic-discharge
(ESD)-preventive measures. These include wearing ESD-preventive gloves, an ESD-preventive wrist
strap, and ESD-preventive clothes to avoid personnel injury or device damage.
To prevent damage to the device, pay attention to the following during operations:
Do not touch devices with bare hands because ESD from the human body may damage the
electrostatically sensitive elements on a board.
When dealing with the server or any of the internal components, wear an ESD-preventive wrist
strap, ESD-preventive gloves, and ESD-preventive suit.
About replacing a power supply in a Veritas appliance
This document describes how to replace a 5150 Appliance power supply while the appliance is
operating. One of the power supplies must be operating at all times. If both power supplies must be
removed at the same time, the shutdown procedure must be performed on the appliance before a
power supply is removed. Contact the Veritas Field Service Coordinators.
This repair can be accomplished with the appliance installed in the rack.
1

Advertisement

loading

Summary of Contents for VERITAS 5150

  • Page 1 About replacing a power supply in a Veritas appliance This document describes how to replace a 5150 Appliance power supply while the appliance is operating. One of the power supplies must be operating at all times. If both power supplies must be removed at the same time, the shutdown procedure must be performed on the appliance before a power supply is removed.
  • Page 2 QRB # 298: Replacing a power supply Caution: You must complete a power supply swap within three minutes. Leaving the power supply slot open for longer than three minutes can result in the appliance overheating and cause other components to fail. Requirements Verify that you have the following items: •...
  • Page 3 QRB # 298: Replacing a power supply Removing a faulty power supply Use the following procedure to remove a faulty power supply. To remove a faulty power supply Verify that the LED on the faulty power supply is amber. If the LED is green or blinking green, the power supply is working properly. Solid green LED indicates that the power supply is currently being used to power the appliance.
  • Page 4: Installing The Replacement Power Supply

    QRB # 298: Replacing a power supply Warning: Swap one power supply at a time only. If you need to remove both power supplies, make sure the appliance is turned off before you proceed. Press in and hold the green release lever on the right side of the power supply to release the module.
  • Page 5 QRB # 298: Replacing a power supply Slide the replacement power supply completely into the slot. The power supply release lever clicks into place when the power supply is properly installed. Plug the power cable into the power supply. The LED should come on and turn green.