3-3.2. Timer Charger Operation - Big Joe PDI Series Operation Maintenance Manual & Parts List

Power drive intermediate lift truck
Table of Contents

Advertisement

3-3.2. Timer Charger Operation.

The batteries must be pulled out of the compartments
in order to check the specific gravity.
Truck Serial Number 342392 To
screw, washer and retainer bar by each battery.
CAUTION:
These batteries are heavy. Use handles
on battery when lifting.
Remove batteries from the right side of the truck. The
battery connecting cables are sufficiently long to allow
batteries to be placed on the floor. It is not necessary
to disconnect the battery cables.
When reinstalling the battery be sure battery cable
connectors are securely attached to the battery termi-
nals, and cables are routed and secured to the battery
as shown in
Figure
3-1.
R5803
3-2
https://forklift-manuals.jimdofree.com
Truck Serial Number 342392 To
and position battery retainer bar to prevent battery
movement in excess of 1/2".
Use the following procedure:
376499, remove
1.
NOTE: These can be obtained from a local hardware
2.
NOTE: Battery specific gravity readings should agree
Figure 3-1 Reinstalling the Battery
Obtain a battery hydrometer.
store or automotive shop.
Use the hydrometer to check specific gravity of
each cell.
within + 0.025 from cell to cell. If variation is
greater, the battery may have to be repaired
or replaced.
USED ON TRUCKS
SERIAL NUMBERS
342392 TO 376499
376499, reinstall
PDI0404

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pdi-2024Pdi-2018

Table of Contents