Installation; Service Connections - Market Forge Industries TURBO STEAM SERIES Installation Operation & Maintenance

Electric countertop convection steamers
Table of Contents

Advertisement

Service Connections

ELECTRICAL CHARACTERISTICS
TS-3E (9kW)
Volts
1 PH
1 PH
AC
9kW
6kW
208
43.3 28.9 25.0
220
40.9 27.3 23.6
240
37.5 25.0 21.7
380
--
--
415
--
--
480
--
--
600
--
--
DIMENSIONS ARE IN INCHES [MM]
20 [508]

INSTALLATION

TS-5E (15kW)
3 PH
3 PH
1 PH
1 PH
9kW
6kW
15kW
10kW
--
72.1 48.1 41.6
--
68.2 45.5 39.4
--
62.5 41.7 36.0
13.7
--
--
--
12.5
--
--
--
10.8
--
--
--
8.7
--
--
--
4 [102]
D
2 [51]
SERVICE CONNECTIONS
E
Electrical Connection - Ø 1-1/8" hole for electrical
connection. Rating to be as specified on data plate.
3 PH
3 PH
15kW
10kW
D
Drain Connection - 1/2" NPT
--
INSTALLATION CLEARANCE
--
Left Side
--
0" (0mm)
22.8
--
20.9
--
18.0
--
14.4
--
16.88 [429]
D
8.5
[216]
Figure 1
2
Right Side
0" (0mm)
25 [635]
E
[610]
4 [102]
2 [51]
VENT
E
TS-3E
2 [51]
19.25 [489]
Rear
3" (76mm)
24
19.13
[486] TS-5E
25.5
[648]
3 [76]