ONLY QUALIFIED TECHNICIANS SHOULD PERFORM THIS FUNCTION!
NOTE ALL MENU SETTINGS BEFORE UPDATING SOFTWARE!
FIXTURE SOFTWARE CAN NOT BE DOWNGRADED!
DOWNLOAD FIXTURE SOFTWARE TO PC ONLY! (NO MAC SUPPORT)
PLEASE CONTACT ADJ CUSTOMER SERVICE FOR FURTHER INFORMATION.
1. Contact ADJ Customer Service to obtain the software update files.
2. Copy the software files to a compatiable USB flash drive.
NOTE: MAKE SURE THESE SOFTWARE FILES ARE THE ONLY FILES LOADED ONTO THE
USB FLASH DRIVE.
3. Disconnect DMX and WiFly connections and power the fixture ON.
4. Insert the USB flash drive into the SERVICE PORT located on the rear panel of the unit.
5. Locate "PERSONALITY" within the system menu and press ENTER. Scroll to the "SERVICE"
submenu and press ENTER. Enter the passcode "50" to gain access.
6. Scroll to the "USB PORT POWER" setting and activate the USB service port by selecting ON.
NOTE: The USB port is OFF by default.
7. After activating the USB port, scroll to "UPDATE SOFTWARE" and press ENTER.
8. Two (2) software files will be displayed as downloaded earlier. Highlight the first file and press ENTER.
Select YES to begin the first of two updating processes. Once YES is selected the display
will show "Updating, Please wait...". A percentage bar will also be displayed.
9. After the first update is complete, the fixture will run a software check (this can take some time).
10. After the software check is complete, the fixture will peform a reset.
11. Once the reset is complete, scroll to the "PERSONALITY" menu again and press ENTER. Scroll
to the "SERVICE" submenu and press ENTER. Enter the passcode "50" to gain access.
12. Reactivate the USB port power if necessary. (See step 6)
13. Scroll to "UPDATE SOFTWARE" setting again and press ENTER.
14. Highlight the second file this time and press ENTER. Select YES to begin the second and final
updating process. Once YES is selected the display will show "Updating, Please wait...".
A percentage bar will also be displayed.
15. After the second update is complete, the fixture will run a software check again.
16. After the software check is complete, the fixture will peform another reset.
17. Remove the USB flash drive.
18. After the reset process is complete check the new software version to confirm it is updated to the
most recent software.