INSTALLATION

Notice before installation

This hood is designed for fitting in a cabinet or on some other support.
Warning: consult local regulations regarding fumes outlets. Do not connect the hood to a
fume, ventilation or hot air duct. Confirm that room ventilation is appropriate with the local
authorities. Make sure the maximum air extraction flow rate for the appliances in the room
does not exceed 4 Pa (0.04 mbar). The room must have adequate ventilation if an extractor
hood is used simultaneously with appliances that run on gas or other fuels. The evacuated
air must be extracted through ducts that are used for evacuating fumes from appliances
that run on gas or other fuels. Regulations regarding air extraction must be complied with.
This product is intended for HOUSEHOLD USE only.
Use a rigid PVC pipe or aluminium pipe with a min. Ø l25 mm or Ø l50 mm to evacuate
fumes outside. The above restrictions do not apply to hoods with no fumes outlet to outside
(recirculation system with activated charcoal filter).
Install the hood in line with the instructions on the template. For gas cooking appliances
only: the minimum distance to the hood must be at least 65 cm.
Warning: Failure to install the screws or fixing device in accordance with these
instructions may result in electrical hazards.
P.4
INSTALLATION
Installation
The cooker hood is supplied with
2 pipe conectors Ø l25 mm or Ø l50 mm
3 Spacer (F, H)
4 Screws (C)
2 Bulbs (LED)
To fixing the Hood, use the 4 screws (C)φ6mm supplied with the hood.
Close the space that remains between the hood and the wall, adjusting the spacer (F).
Before completing any connection, make sure the house voltage corresponds with the
voltage indicate on the data label.

Connecting the hood to the grid

Warning: before connecting the hood: switch off the electricity supply and check
that the supplied voltage and frequency coincide with that indicated on the appliance
nameplate.
If the extractor hood has a plug, connect it to a power socket in line with applicable
regulations, located in an accessible area.
If the terminals of the plug are unmarked or if you are in any doubt consult a qualified
electrician.
If it is not supplied fit a plug normalized in the cord for the load showed on the rating label.
P.5