Installation Instructions

Pre-installation Notice
The range hood must be installed and repaired by authorized qualified technicians.
Before installation, plug in and check if all switches are functional.
Installation Environment
For efficient air extraction, avoid opening too many windows surrounding range hood for this will cause
air convection which prevents cooking fumes from rising to 25 cm (the effective suction / exhaust
area).
Installation Method
Drill holes in the wall according to the distance between the 2 mounting brackets and the diameter of
the 2 holes on the mounting bracket. Install the anchor screws in the holes. Fix the range hood onto
the screw and secure with nuts (Fig A.B.C).
Height of Installation
The appliance should be positioned 700±50mm above the cooking range. A distance that is near
700mm results in higher venting efficiency (Fig D).
Keep the Hood Level
The installation of the hood should remain level, in order to prevent oil from spilling over from oil collec-
tors (Fig E).
Length of Exhaust Pipe
The connection opening at the top of the range hood must be connected to the exhaust pipe for ex-
hausting fumes to the outdoors. Exhaust pipe of 6 inches in diameter should be used. The length of the
exhaust pipe should be minimized to avoid air turbulence inside the pipe (Fig F).
Fig A
Fig B
Fig C
281mm
252mm
Fig D
Fig E
Fig F
Level
Tilted
P.6

Wiring Diagram

Plug
Motor
Control box
Heater sensor
LED
LED
Capacitor
50 60 Hz 450VAC
/
Infrared sensor
Switch button