Resupply Of Water; Detection Of Overflow; Water Level For Heating Cycle - Daewoo MINI Series Service Manual

Wall-mounted front-load washer
Table of Contents

Advertisement

3) Resupply of Water

1 The water level is measured every two minutes after the initial water supply to add water if the level is
lower than the pre-determined level.
2 The motor stops running during the resupply of water.
3 Water is resuppliable up to 20 times during wash. On the occurrence of the 21st water supply, the "E4"
error is displayed and the wash cycle is suspended. -> This error doesn't usually take place because of the
short duration of wash program.
- Start the pump on the occurrence of the "E4" error.
4 If the water level is below the reset level during the resupply of water, the 'IE' error is displayed and the
heater is turned off.

4) Detection of Overflow

1 The water level is measured every two minutes after the initial water supply to drain water if the level is
above the overflow level.
2 If the water level is measured above the overflow level three times, the 'E3' error is displayed and the wash
cycle is suspended. However, the water continues to be drained.
3 If the water level is first measured to be above the overflow level during the "Baby Care" program, the
heating cycle is skipped. The 'E3' error is displayed on the third occurrence of overflow detection, and the
wash cycle is suspended. However, the water continues to be drained.
4 If the water level is measured to be above the overflow level when the wash cycle is suspended, the 'E2'
error takes place but the water continues to be drained.

5) Water Level for Heating Cycle

1 If the water level is measured below the preset level, the heater is turned off to prevent overheating or short
circuit during the heating cycle.
20

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mini 1.0Mini 1.5

Table of Contents