Inspection And Repairs Of Water Inlet Valve; Defects And Relevant Parts - Daewoo MINI Series Service Manual

Wall-mounted front-load washer
Table of Contents

Advertisement

3) Inspection and Repairs of Water Inlet Valve

Defects
Descriptions
Water supply
Water is not
unavailable
supplied despite
the "drone"
Water supply
Water supply
unavailable
continues with
the power "ON"
Constant
Power is "OFF"
water supply
Constant leaks
(into tub)
on sides
Others

4) Defects and Relevant Parts

Unavailable
PCB
water
supply
Incessant
PCB
water
supply
Inlet Valve 1. Examine whether the water
Synchronous
Drain Motor
(Valve
Housing)
Causes
Faucet is turned off. Check whether the faucet is turned on
Short coil
Excessive impurities
on SUS filter
Impurities in valve
Disconnected
connector
Coil wire
Disconnection in
wiring
Defective water
level sensor
Inspect any openings and
blockages in pressure hoses
Defective valve
Check any leaks
from the sides of
inlet valve
1. Inspect the insertion of
PCB pin
2. Unavailable power or
water supply to inlet valve
terminal
1. Water supply starts
promptly when the power
is turned "ON".
supply continues even when
the power supply is cut off
1. Examine the operation/
water supply of inlet valve
2. Examine the drainage
through the drainage hose
3. Check any impurities in
valve housing
Inpsection Method
Check whether the inter-terminal
resistance of inlet valve is 4.3kΩ
Unplug the inlet hose and then check
the impurities
Check the malfunctions in valve
Check the connection of connector
with naked eyes
Check whether the inter-terminal
resistance of inlet valve is 4.3kΩ
Check any disconnections in wiring
-> Inspect circuit
See the inspection of "Water Level"
defects
Inspect any openings and blockages
in pressure hoses
Check the malfunctions in valve
Check any leaks from the sides of
inlet valve
Easily detachable if the
wire is pulled
Open or destroyed PCB
inlet circuit (Water relay
unavailable)
Short circuit in PCB
inlet circuit or water
relay (Incessant electric
transmission to valve)
Deformed water inlet
valve bellows
• Unclosed due to
impurities in
drainage housing
40
Repair Method
Turn on the faucet
Exchange the part if
it is open
Remove impurities
and "cleanse" the filter
Exchange the inlet valve
Reconnect the
connector
Exchange the inlet
valve
Exchange the
harness
Exchange the water
level sensor
Exchange the
defective part
Exchange the inlet valve
Exchange the inlet
valve
Housing on pin
Insert the housing
connection not
on pin connection
properly inserted
completely
Defective inlet
Exchange the PCB
circuit
Short circuit in
Exchange the PCB
water relay
Defective inlet
Exchange the inlet
valve
valve
• Impurities in
• Remove impurities
valve housing
• Impurities
• Remove impurities
• Error in returns
• Exchange the
of synchronous
synchronous motor
motor
PCB Error
Mode
"IE"
"IE"
"IE"
"IE"
"IE"
"IE"
"IE"
"E2"
"E2"
-
-

Hide quick links: