4) In the event of OE after remdy, follow the below directions.
Inspection method: Remove the join area around "100mm" from the hose drain.
After removal, clean the area where the foreign object was located .
HOSE DRAIN * O
5) Cleaning and Exchange of Drain Housing
[Disassembly]
1 Push the stopper of housing and turn the motor base counterclockwise to detach the bellows.
2 Examine the inside to remove any impurities.
3 Exchange only the motor if the motor causes poor operation.
[Assembly] Re-assemble the parts in the opposite sequence to disassembly.
(100mm)
STOPPER
Drain Motor + bellows Assembly
38
Clean the
area
BASE+MOTOR