IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11
IEC 61000-4-12
IEC 61000-4-16
IEC 61000-4-17
IEC 61000-4-18
IEC 61000-4-29
EMC Immunity Type Tests per IEEE 1613
Note
The RUGGEDCOM RSG2100P meets Class 2 requirements for an all-fiber configura-
tion and Class 1 requirements for copper ports. Class 1 allows for temporary commu-
nication loss, while Class 2 requires error-free and interrupted communications.
RUGGEDCOM RSG2100P
Installation Manual, 01/2020, C79000-G8976-1041-16
Test
Induced (Con-
ducted) RFI
Magnetic Field
Voltage Dips
and Interrupts
Damped
Oscillatory
Mains Frequen-
cy Voltage
Ripple on DC
Power Supply
Damped Os-
cillatory Wave
Voltage Dips
and Interrupts
IEC 60255-5
Dielectric Strength
HV Impulse
6.2 EMC and Environmental Type Tests
Description
Signal Ports
DC Power Ports
AC Power Ports
Earth Ground Ports
Enclosure Ports
AC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Signal Ports
AC and DC
Power Ports
DC Power Ports
Slow Damped
DC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Certification
Test Levels
Severity Levels
10 V
100 A/m
Continuous
1000 A/m for 1 s
30% for 1 period
60% for 50 periods
100% for 5 periods
100% for
50 periods
2.5 kV Common
1 kV Differential
Mode @1 MHz
30 V Continuous
300 V for 1s
10%
2.5 kV Common
Mode on Pow-
er and Signal
1.0 kV Differential
Mode on Power
30% for 0.1 s
60% for 0.1 s
100% for 0.05 s
2 kV (Fail-Safe
Relay Output)
2 kV
2 kV
5 kV (Fail-Safe
Relay Output)
5 kV
3
5
 
3
4
3
3
 
 
 
 
 
 
 
45