Connection Possibilities - Festo CPX-FB13 Electronic Manual

Field bus node
Hide thumbs Also See for CPX-FB13:
Table of Contents

Advertisement

1. Installation

1.3.4 Connection possibilities

1−22
Please note
Use a protective cap or blanking plug to seal unused con
nections. You will then comply with protection class IP65.
Connection with field bus plugs from Festo
Observe the fitting instructions for the field bus plug.
·
Tighten the two fastening screws at first by hand and then
with max. 0.4 Nm.
You can connect the CPX terminal easily to the field bus with
the field bus plug from Festo (type FBS−SUB−9−GS−DP−B, part
no. 532216). You can disconnect the plug from the node with
out interrupting the bus cable (T−TAP function).
Please note
The clamp strap in the field bus plug from Festo is con
nected internally only capacitively with the metallic hous
ing of the sub−D plug. This is to prevent equalizing currents
flowing through the screening of the field bus cable.
Festo P.BE−CPX−FB13−EN en 0503b