Ignition; Control Panel - Kalor Cloe 17B User Manual

Wood pellet boiler stove
Table of Contents

Advertisement

Available languages

Available languages

Hydro Insert ignition
Remove any components which might burn from the fi rebox and from the glass
(various instructions and adhesive labels)
Charge pellet
Fuel is loaded from the upper part of the Hydro Insert by opening a door. Pour the pellets in the hopper. When empty, this
is easier if performed in two steps:
• Pour half of the contents of the bag into the hopper and wait for the fuel to settle on the bottom.
• Then pour in the rest.
Never remove the protection grille in the hopper. When fi lling, do not let the sack
of pellets touch any hot surfaces.
The brazier should be cleaned before each starting.

Control Panel

(Fig. 2)
Button
is used to switch on and / or off the Hydro Insert and to exit programming.
is used to switch on and / or off the Hydro Insert and to exit programming.
is used to switch on and / or off the Hydro Insert and to exit programming.
is used to switch on and / or off the Hydro Insert and to exit programming.
is used to switch on and / or off the Hydro Insert and to exit programming.
Buttons
and
Buttons
and
Button
e
is used to adjust temperature and programming functions.
The upper and lower displays are used to view different messages.
LED
SYMBOL
The LED is on when the parameter UT01 on the menu is not on OFF and the weekly or daily
1
programming are set.
2
The LED starts up every time the Hydro Insert is loading pellets
The LED blinks when the board signalises a change in temperature or power set by the infrared
3
remote control.
4
The LED is on when the room temperature reaches the value set on the menu SET Water.
The LED blinks to indicate that you are entering the menu user/technician or that you are modifying
5
SET
the temperature set.
6
The LED switches on when the water circulator is working.
It is advisable to use dry wood pellets, up to 6 mm in diameter.
120
are used to adjust temperature, for displays and for the programming functions.
are used to adjust temperature, for displays and for the programming functions.
are used to adjust heating power.
1
DESCRIPTION
Fan
acc