Failure On Electrical Devices; Manual Restart Thermostat; Switching Off While Working; There Is No Power Supply - Kalor Cloe 17B User Manual

Wood pellet boiler stove
Table of Contents

Advertisement

Available languages

Available languages

Failure on electrical devices

Mancata accensione
If the fl ame does not light up during the switching on or if the smokes temperature does not reach a suitable value in the
foreseen time gap, the Hydro insert switches off and you will read the words "
on the display. Press the key "On/Off" to reset the alarm. Wait until the cooling phase is completed, clean the brazier and
start a new light-up.

Switching off while working

The Hydro insert suddenly switches off while working (for example because it has run out of pellets in the tank or because
the motor reducer for pellets loading got broken). The Hydro insert continues working until the pellets left in the brazier
ends. You will then read the words "
reset the alarm. Wait until the cooling phase is completed. Clean the brazier and start a new light-up.
These alarms remind you that the brazier must be cleaned and installed correctly before switching on the
Hydro insert.

There is no power supply

In the event of a power drop longer than one minute, the Hydro insert can exhaust some smoke in the room: this causes no
risks. As soon as you have the power supply again, the Hydro insert will have the words "
After completing the cooling phase, the Hydro insert will start up again automatically according to the previous settings.o
precedente all'assenza di
Do not attempt to start the Hydro insert before the required time or it may get
blocked. If this occurs, switch off the switch on the back of the pellet Hydro
insert stove for 1 minute, set it on again and wait 10 minutes before starting
the Hydro insert again.
The power socket where the Hydro insert is connected should be fi tted with
"earth connection complying with regulations in force." The Manufacturer shall
not be held responsible for damage to things or people resulting from negligent
installation.

Manual restart thermostat

Intervention in case of danger
In case of fi re, disconnect the power supply, use a fi re
extinguisher in accordance with, and if necessary, call the
fi re department and then contact an authorised qualifi ed
technical assistance
n o pe l l e t
elettricità.
"on the display and the stove switches off. Press the key "On/Off" to
N O L IGH TI N
".
B L ACK OU T
RESTART
WATER
" on the display.
127

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Petra 25b

Table of Contents