Download Print this page

Controller Mounting Plate - Konica Minolta IC-401 Installation Manual

Image controller with vi-501 interface kit for c350
Hide thumbs Also See for IC-401:

Advertisement

■ Installing the Fiery Controller Board
NOTE
C4342U235AA
Required tool:
• Phillips screwdriver
C4342U202AA
Image Controller IC-401 (Interface Kit VI-501)
Start the installation procedure after removing 4
plastic from the four corners of the controller
mounting plate.
1. Attach the Fiery controller board to the con-
troller mounting plate using the three shoul-
der screws (11) by tightening them in the
following order: ➀, ➁, then ➂.
NOTE
Be sure to use the enclosed shoulder screws
(part number 11 in the contents list).
Shoulder Screw (11)
C4025U905AA
C4342U203AA
C4342U204AA
C4342U205AA
– 6 –
2. Secure the Fiery controller board with the
six screws (7).
3. Secure the IEEE1284 connector to the con-
troller mounting plate using the two screws
enclosed with the Fiery controller board.
NOTE
These two screws are provided with the Fiery
Controller.
4. Connect the two connectors.