Switch off the drilling
machine on the main
switch or disconnect the
mains plug.
Move the drill sleeve
down.
Turn the drilling spindle
until the openings of the
sleeve and of the drilling
spindle are superimposed.
Loosen the taper mandrel
of the drill chuck with the
help of a drill drift.
Inserting the Drill Chuck
Clean the conical seat on the drill spindle and in the drill chuck. Both cones must be free of
grease and dirt.
Push the drill chuck with a firm push into the holding fixture.
4.5

Inspection and maintenance

Interval
every 50 hours
as required
according to operator's, in
accordance with German
DGUV (BGV A3)
Operation
Version 1.0.1 dated 2016-04-25
Drill drift
Drill sleeve
Drill chuck or drill
Img.4-3:
Disassembly DX15V
Where?
What?
Spindle, Table
Oiling
mount, Column
Drill Head
Cleaning
Housing
Electrical
Electronics
inspection
Original operating instructions
OPTIMUM
M A S C H I N E N - G E R M A N Y
How?
With non-corroding oil
with plastic cleaning agents

"Obligations of the operating company" on
page 7

"Electrical system" on page 10

"Electrical connection" on page 16
DX13V | DX15V