SPECIAL FUNCTIONS
Waterproof (IP65)
Auto range (Full range)
Illumination (Full range)
Low battery indication
(About 2.4V)
Over range indicaton
(About 755V)
Auto standby
(Standby current <10µA)
Silent mode (Full range)
Backlight (Full range)
LCD display (voltage) 6V~690V
LCD display (frequency)
40Hz~400Hz
LCD DISPLAY & PARAMETER DESCRIPTION
Range
6V
72-3575 ± (1.5% + 1) ± (1.5% + 2) ± (1.5% + 3) ± (1.5% + 4)
72-3580 ± (1.5% + 1) ± (1.5% + 2) ± (1.5% + 3) ± (1.5% + 4)
FUNCTION & PARAMETER DESCRIPTION
LED voltage range
LED voltage indication point
LCD voltage range
Frequency measurement range 40Hz~400Hz, resolution: 1Hz, error: ± (3% + 5
Voltage measurement
Buzzing & Silent mode
Polarity indication
Range selection
Response time
Peak current of test circuit
Test time
72-3570
12V/24V
50V
12V~690VAC/DC
12V, 24V, 50V, 120V, 230V, 400V, 690V
6V~690V AC/DC (72-3575/72-3580),
resolution:1V, voltage error: ± (1.5% + 1~5 digits)
digits)
Auto
Optional
Auto
Auto
LED <0.1s / LCD <1s
1s < 3.5mA (AC/DC)
30 seconds
10
72-3575
± (3% + 5)
120V
230V/400V/690V
± (1.5% + 5)
± (1.5% + 5)
72-3580
± (3% + 5)