Special Functions; Lcd Display & Parameter Description; Function & Parameter Description - Tenma 72-3575 Manual

Voltage & continuity tester
Table of Contents

Advertisement

SPECIAL FUNCTIONS

Waterproof (IP65)
Auto range (Full range)
Illumination (Full range)
Low battery indication
(About 2.4V)
Over range indicaton
(About 755V)
Auto standby
(Standby current <10µA)
Silent mode (Full range)
Backlight (Full range)
LCD display (voltage) 6V~690V
LCD display (frequency)
40Hz~400Hz
LCD DISPLAY & PARAMETER DESCRIPTION
Range
6V
72-3575 ± (1.5% + 1) ± (1.5% + 2) ± (1.5% + 3) ± (1.5% + 4)
72-3580 ± (1.5% + 1) ± (1.5% + 2) ± (1.5% + 3) ± (1.5% + 4)
FUNCTION & PARAMETER DESCRIPTION
LED voltage range
LED voltage indication point
LCD voltage range
Frequency measurement range 40Hz~400Hz, resolution: 1Hz, error: ± (3% + 5
Voltage measurement
Buzzing & Silent mode
Polarity indication
Range selection
Response time
Peak current of test circuit
Test time
72-3570
12V/24V
50V
12V~690VAC/DC
12V, 24V, 50V, 120V, 230V, 400V, 690V
6V~690V AC/DC (72-3575/72-3580),
resolution:1V, voltage error: ± (1.5% + 1~5 digits)
digits)
Auto
Optional
Auto
Auto
LED <0.1s / LCD <1s
1s < 3.5mA (AC/DC)
30 seconds
10
72-3575
± (3% + 5)
120V
230V/400V/690V
± (1.5% + 5)
± (1.5% + 5)
72-3580
± (3% + 5)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

72-357072-3580

Table of Contents