SINGLE TEST PEN TESTING

For single test pen testing, hold L2 and connect L2 to an unknown conductor.
If the voltage of the conductor under test is higher than 100V AC, the LED (72-
3570/72-3575) or high-voltage symbol will illuminate and the meter will buzz.
To determine if a conductor is live, with a single pen, contact the L2 probe tip with
the conductor under test.
If the AC light (72-3570/72-3575) illuminates, or the "
displayed on the LCD, it means that the wire measured is a live wire.
To determine if the socket is electrified, insert L2 into the terminal. If the AC light
or "
" symbol is displayed along with continuous beeping, it means the socket is
live.
Notes:
Single test pen testing can only determine whether or not a conductor is live. It
cannot indicate the voltage level.
In the presence of adverse environmental factors such as temperature, humidity,
magnetic field, static electricity and others, the single test pen will show an
unstable reading.
When the measured conductor is >200VAC, the buzzer will remain silent, while the
AC LED will illuminate and a low voltage reading will be displayed.
The LCD may display a reading (72-3575/72-3580), but the voltage value should
not be considered as the actual measured value as it is simply indicating the
conductor is electrified.
DETECTION WITHOUT BATTERIES (72-3570/72-3575 only)
The tester may perform basic measurements with no battery power.
Connect the two test pens to the circuit under test. If the circuit has a voltage
≥50VAC/120VDC the high voltage LED will illuminate, indicating a dangerous
voltage.
The LED brightness will be proportional to the voltage measured.

CONTINUITY TEST

To confirm if the conductor to be measured has continuity, the meter can test for
this.
Connect the two test pens to both ends of the object to be measured; if the
resistance is 0~100kΩ, the continuity LED (72-3570/72-3575) will illuminate or
the continuity symbol (72-3580) will display on the LCD and the buzzer will sound
continuously.
If the resistance is >150kΩ, the continuity LED (72-3570/72-3575) will not
illuminate or the continuity symbol (72-3580) will not display and the buzzer will not
sound.
Prior to any test, be sure the object to be measured is not live.
" symbol (72-3580) is
6

Hide quick links: