Procedure
Perform the following steps to configure the TSSC.
80
IBM System Storage TS7650 ProtecTIER Deduplication Appliance: Installation Roadmap Guide
1. If the TSSC is not already powered-on, do so now.
Note: When powering on the TSSC, several hardware checks run
automatically. During these checks, failure indications are displayed for the
Eclipse Framework and AOTM. These failure indications can be ignored, as
they are normal and do not interfere with the operation of the TSSC or its
communication to the ProtecTIER server. Failure indications other than those
noted require attention. Identify any failing routines and, if needed, contact
your next level of support.
2. If prompted for login information, enter the username: service and the
password: service.
The TSSCs blue desktop displays. See Figure 45 on page 81.
3. Configure the TSSC for Call Home. Before doing so, take note of following
important information:
v The Call Home setup procedure has been revised. If outdated procedures
are used, the total Call Home solution might not be enabled and the process
fails. To ensure that you are using the most current instructions, refer to the
relevant sections in the IBM System Storage TS3000 System Console (TSSC)
Maintenance Information, provided on the IBM System Storage TS7650 with
ProtecTIER Publications CD.
v Do not select the Software Call Home check box unless you are certain
your support center supports sending Software Call Home events down the
hardware entitlement path. Enabling the routing of Software Call Home
calls down the hardware entitlement path might cause software entitlement
issues. While this option might be supported for customers in Europe or
Asia, it is not supported in the United States.
With consideration of the preceding statement regarding your region, select
the Software Call Home check box in the TSSC Setup GUI to set the
software Call Home flag. If the flag is not set, software problems must be
reported by the customer. When a software problem is detected, the logs are
collected and stored on the TSSC in this location: /var/enc/SWCH.
4. When Call Home setup is complete, return to this page and go to step 5.
5. Right-click the TSSC blue desktop.
The IBM TS3000 System Console menu displays. See Figure 45 on page 81.
6. Click System Console Actions > Console Configuration Utility.