Ethernet Connections - IBM TS7650 Installation Roadmap Manual

System storage protectier deduplication appliance
Hide thumbs Also See for TS7650:
Table of Contents

Advertisement

Procedure
Perform the following steps verify the power connections.
1. Use Table 20 on page 49 and Figure 29 on page 48 to verify the power
2. Make any necessary adjustments to cable placement or labeling, then go to

Ethernet connections

The tasks in this section describe the network Ethernet connections to the 1-Gb
Ethernet switches, the TSSC, and the customer network for both VTL and
OpenStorage with the TS7650 Appliance server in a clustered configuration.
1 Gb Ethernet switch connections
This task describes the 1-Gb Ethernet switch connections for the TS7650 Appliance
server in a clustered configuration.
Notes:
v Depending upon the model of the TSSC and TSSC network switch being used,
v Connection of the replication network cables is required only if the customer is
1-Gb Ethernet switch connections in a VTL configuration:
This task shows the Ethernet cabling for the 1-Gb Ethernet switches in a clustered
TS7650 Appliance for VTL configuration.
About this task
Note: Depending upon the model of the network switch being used, the port
layout might differ from what is shown in Figure 30 on page 51. If so, label the
50
IBM System Storage TS7650 ProtecTIER Deduplication Appliance: Installation Roadmap Guide
Table 20. Clustered power connections (continued)
Label
From
27
EXPB2-2 P1
EXPB2-3 P1
connections made in manufacturing.
Important:
a. All power connections from the TS7650 components to the PDUs and to the
WTI network power switch were completed in manufacturing.
b. In the following diagram, the letters TJ followed by a number (for example:
TJ5) indicate which outlet the associated component plugs into on the Top
PDU. The letters BJ followed by a number (for example: BJ8) indicate which
outlet the associated component plugs into on the Bottom PDU.
c. TSSC power cable TJ5 might not be present in the ship group. If not,
connect the TSSC to the PDU by using only power cable BJ5.
"Ethernet connections."
the port layout might differ from what is shown in Figure 30 on page 51 or
Figure 31 on page 53. If so, make the cable connections according to the port
number assignments specified in Table 21 on page 51 or Table 22 on page 53,
regardless of the position of the ports on the switch. Refer to the IBM System
Storage TS3000 System Console (TSSC) Maintenance Information for detailed port
information.
enabling the data replication feature.
To
Top PDU J7
Remarks
Bifurcated cable