Wayne 332200-001 Operating Instructions & Parts Manual

Sewer ejector pump

Advertisement

Quick Links

Operating Instructions & Parts Manual
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or
maintain the product described. Protect yourself and others by observing all safety information. Failure to
comply with instructions could result in personal injury and/or property damage! Retain instructions for future
reference.
Description
The submersible pump is designed
for home applications. The unit is
equipped with a 3-prong grounding
type power cord. Motor is oil-filled and
sealed for cooler running and designed
to operate under water. This pump is
not suitable for aquatic life, ponds or
fountains.
Unpacking
Inspect this unit before it is used.
Occasionally, products are damaged
during shipment. If the pump or
components are damaged, return
the unit to the place of purchase for
replacement. Failure to do so could
result in serious injury or death.
Important Safety
Instructions
READ AND FOLLOW ALL INSTRUCTIONS

Safety Guidelines

This manual contains information
that is very important to know and
understand. This information is
provided for SAFETY and to PREVENT

Specifications

Power supply requirements
SEP4 . . . . . . . . . . . . . . . . . . . . . . . . 120V, 60 hz
SEP5, SEP6, and SEP8 . . . . . . . . . . 240V, 60 hz
Motor . . . . . . . . . . . . . . . . . . . . . . . . Single phase, oil filled
Horsepower/Current
SEP4 . . . . . . . . . . . . . . . . . . . . . . . . 1/2 HP, 12A @ 115VAC
SEP5 . . . . . . . . . . . . . . . . . . . . . . . . 3/4 HP, 7A @ 230VAC
SEP6 . . . . . . . . . . . . . . . . . . . . . . . . 1 HP, 8.5A @ 230VAC
SEP8 . . . . . . . . . . . . . . . . . . . . . . . . 2 HP, 12A @ 230VAC
Liquid temperature range . . . . . . . 40°F to 120°F
Circuit requirements . . . . . . . . . . . . 15 amps (min)
Dimensions. . . . . . . . . . . . . . . . . . . . . . 11 1/2 in. high x 9 3/4 in. base
© 2009 Wayne Water Systems
Sewer Ejector
Pump
EQUIPMENT PROBLEMS. To help
recognize this information, observe the
following symbols:
hazardous situation which, if not avoided,
WILL result in death or serious injury.
hazardous situation which, if not avoided,
COULD result in death or serious injury.
hazardous situation which, if not avoided,
MAY result in minor or moderate injury.
information, that if not followed, MAY
cause damage to equipment.
General Safety
Information
CALIFORNIA PROPOSITION 65
contain chemicals known to the State
of California to cause cancer and birth
defects or other reproductive harm.
Wash hands after handling.
REMINDER: Keep your dated proof of purchase for warranty purposes!
Attach it to this manual or file it for safekeeping.
For parts, product & service information
visit www.waynepumps.com
GENERAL SAFETY INFORMATION
pump fl ammable or explosive
Danger indicates an
fl uids such as gasoline, fuel
imminently
oil, kerosene, etc. Do not
use in a fl ammable and/or explosive
atmosphere. Personal injury and/or
Warning indicates a
property damage could result.
potentially
Caution indicates a
to handle salt water, brine, laundry
potentially
discharge or any other application
which may contain caustic chemicals
and/or foreign materials. Pump damage
Notice indicates
could occur if used in these applications
important
and will void warranty.
qualifi ed electrician.
basement has water or
moisture on the fl oor, do not
This product or
walk on wet area until all
its power cord may
power is turned off. If the shut-off box
is in the basement, call an electrician.
Remove pump and either repair or replace.
Failure to follow this warning could result
in fatal electrical shock.
Construction
Motor housing . . . . . . . . . . . Cast Iron
Volute . . . . . . . . . . . . . . . . . . Cast Iron
Impeller . . . . . . . . . . . . . . . . . Cast Iron
Shaft . . . . . . . . . . . . . . . . . . . Low carbon steel
Seals . . . . . . . . . . . . . . . . . . . . Buna N
Discharge . . . . . . . . . . . . . . . 3 in. NPT
SEP4, SEP5,
SEP6 and SEP8
Do not
use to
This pump is
not designed
All wiring must be
performed by a
If
the
2 in. NPT (Adapter included)
332200-001 2/09

Advertisement

Table of Contents
loading

Summary of Contents for Wayne 332200-001

  • Page 1: Safety Guidelines

    Dimensions..... . 11 1/2 in. high x 9 3/4 in. base REMINDER: Keep your dated proof of purchase for warranty purposes! © 2009 Wayne Water Systems Sewer Ejector Pump EQUIPMENT PROBLEMS.
  • Page 2: General Information

    Operating Instructions and Parts Manual General Information Sewage Pump Systems: Simplex System A simplex system consists of one pump, its control switch, and one basin. It is used in applications where less than six toilets (units) are discharged into a basin. The simplex unit is generally operated with a contactor to turn the pump ON and OFF.
  • Page 3: Operation

    Operating Instructions and Parts Manual Installation (Continued) INSTALLATION BASICS: 1. NEVER lift this product by the electrical cords. 2. Install pump in a sewage pit that fulfills the minimum size requirements (24 in. minimum). Construct sump pit of tile, concrete, steel or plastic.
  • Page 4: Maintenance

    Operating Instructions and Parts Manual Operation (Continued) 2. With the cover removed, add water to the basin and observe the float control switch operation. 3. Also, test alarm switch if installed. 4. Secure and seal basin cover. Do not run your pump in a dry sump. Do not attempt to oil the motor.
  • Page 5: Troubleshooting Chart

    Operating Instructions and Parts Manual Troubleshooting Chart Symptom Possible Cause(s) Pump will not start or run 1. Blown fuse, tripped breaker 2. Low line voltage 3. Defective motor 4. Defective float switch 5. Stuck/ jammed impeller 6. Float obstructed Pump starts and stops too 1.
  • Page 6 Shaft seal kit Seal plate Cover gasket Capacitor 3/4 HP to 2 HP 1/2 HP only www.waynepumps.com Address any correspondence to: Wayne Water Systems 101 Production Drive Harrison, OH 45030 U.S.A. Ref. Part Number Qty Description 16314 Motor housing 23124...
  • Page 7 Operating Instructions and Parts Manual Notes www.waynepumps.com...
  • Page 8: Limited Warranty

    Limited Warranty For one (1) year from the date of purchase, Wayne Water Systems will repair or replace, at its option, for the original purchaser any part or parts of its Sump Pumps or Water Pumps (“Product”) found upon examination by Wayne Water Systems to be defective in materials or workmanship.

This manual is also suitable for:

Sep4Sep5Sep6Sep8

Table of Contents