To set parameters, press the [Func] and [Print] keys at the same time.
7.1

INCREMENT VALUE

• The first parameter on setting the increment value will be
displayed as "Inc xx" where xx can be 1, 2, 5 or 10. The first value
shown is the default scale increment value.
• To change to a different increment value press [Tare/ ].
• Press the [Zero/Enter] key to store the changed value and move
to the next parameter.
7.2

CONTROL THE BACKLIGHT

• The standard is to have the backlight operate automatically i.e.,
turning it off when the scale is not being used.
• The backlight can be set to be "EL on" (always on), "EL AU"
(Automatic) or "EL oFF" (always off). The maximum battery life is
achieved with the backlight turned off.
• Press the [Tare/ ] key to change the setting.
• Press the [Zero/Enter] to store the changed setting and move to
the next parameter.
7.3

AUTOMATIC ACCUMULATION

• With "Au on" the memory will accumulate the weight automatically.
• "Au oFF" will enable the manual accumulation.
• "P Cont" will set the RS-232 interface to send the weight
continuously and the accumulation function is disabled.
• Press the [Tare/ ] key to change the setting.
• Press the [Zero/Enter] key to store the changed setting and
move to the next parameter.