CBW SERIES
(P.N. 4276, Rev. B8, November 2006)
Software rev.: 1.2- 2.04
(For CBW 6H, rev.:1.4-3.00)
© Inscale Measurement Technology Ltd 2007
www.inscale-scales.co.uk

Advertisement

Table of Contents
loading

Summary of Contents for Adam Equipment CBW Series

  • Page 1 Inscale Measurement Technology www.inscale-scales.co.uk CBW SERIES (P.N. 4276, Rev. B8, November 2006) Software rev.: 1.2- 2.04 (For CBW 6H, rev.:1.4-3.00) © Inscale Measurement Technology Ltd 2007 www.inscale-scales.co.uk...
  • Page 2 © Adam Equipment Company 2006...
  • Page 3: Table Of Contents

    CONTENTS INTRODUCTION......................3 SPECIFICATIONS ......................4 INSTALLATION......................5 LOCATING THE SCALE ....................5 INSTALLATION OF CBW SERIES................5 KEY DESCRIPTIONS ....................6 DISPLAYS ........................8 OPERATION ........................8 ZEROING THE DISPLAY ...................8 TARING ........................9 WEIGHING A SAMPLE ....................9 PERCENT WEIGHING ....................9 PARTS COUNTING ....................10 CHECK-WEIGHING ....................10 6.6.1 Setting up Check-weighing while weighing............11 6.6.2...
  • Page 4 © Adam Equipment Company 2006...
  • Page 5: Introduction

    1.0 INTRODUCTION • The CBW series of scales provide an accurate, fast and versatile series of general purpose weighing scales with counting, % weighing and check-weighing functions. • There are 6 models in each series with capacities up to 45 kg.
  • Page 6: Specifications

    Scale Housing ABS Plastic, Stainless Steel platform Pan Size 225 x 275 mm Overall Dimensions 315 x 355 x 110 mm (wxdxh) Net Weight 4.1 kg Applications Weighing Scales Functions Weighing, parts counting, % weighing, Checkweighing © Adam Equipment Company 2006...
  • Page 7: Installation

    Keep the scales clean. Do not stack material on the scales when they are not in use. INSTALLATION OF CBW SERIES • The CBW Series comes with a stainless steel platform packed separately. • Place the platform in the locating holes on the top cover.
  • Page 8: Key Descriptions

    This is the net weight. © Adam Equipment Company 2006...
  • Page 9 CBW series. For CBWa scales this key will select kilograms, grams, Pounds and Pounds/ounces weighing unit, enabled. This should only be done in gross weighing or at zero. © Adam Equipment Company 2006...
  • Page 10: Displays

    However you may need to press the [Zero/Enter] key to re-zero the scale if small amounts of weight are still shown when the platform is empty. © Adam Equipment Company 2006...
  • Page 11: Taring

    100.00%, however a small change of weight will cause the display to jump to 102.13% as one scale division (0.5g) increase to 24.0g will be equivalent to an increase of 2.13%. • Pressing [Func] will return the scale to weighing. © Adam Equipment Company 2006...
  • Page 12: Parts Counting

    NOTE: The alarm can be set to OFF (See the section 7.7 on Parameter). In this case the display will indicate whenever the weight is within or exceeds the limits by showing ‘OK’, ‘HI’ or ‘LO’. © Adam Equipment Company 2006...
  • Page 13: Setting Up Check-Weighing While Weighing

    The beeper will never sound and the display will show LOW IS SET LO if the weight is less that the Low Limit and HI if the GREATER THAN weight is greater than the Low Limit. HIGH © Adam Equipment Company 2006...
  • Page 14: Setting Up Checkweighing While Parts Counting

    • The accumulated weights will be stored in the master unit of the scale, i.e. kg or lbs. • If at any time the weighing units are changed, the accumulated data will be lost. © Adam Equipment Company 2006...
  • Page 15: Manual Accumulation

    The total will also be printed via the RS-232 interface. • To erase the memory, press [Print] to view the totals and then press the [Func/C] key to clear the memory. © Adam Equipment Company 2006...
  • Page 16: Automatic Accumulation

    • Enable the accumulation when [Print] is pressed or to disable. • Set a range for auto zero. • Select another weighing unit than the standard. • Set the check weighing alarm. • Set the speed. © Adam Equipment Company 2006...
  • Page 17: Increment Value

    • "P Cont" will set the RS-232 interface to send the weight continuously and the accumulation function is disabled. • Press the [Tare/ ] key to change the setting. • Press the [Zero/Enter] key to store the changed setting and move to the next parameter. © Adam Equipment Company 2006...
  • Page 18: Accumulation Of Data In Memory When [Print] Is Pressed

    • The display will show “Ut on” or “Ut oFF”. • Press [Tare/ ] to change the setting between on or oFF. • Press the [Zero/Enter] key to store the changed setting and move to the next parameter. © Adam Equipment Company 2006...
  • Page 19: Setting Of The Check Weighing Alarm

    15. The display will show “SPd 15”. • To change this setting press the [Tare/ ] key. • Press the [Zero/Enter] key to store the changed value and return to the normal weighing. © Adam Equipment Company 2006...
  • Page 20: Battery Operation

    • As the battery is used over the years it may fail to hold a full charge. If the battery life becomes unacceptable then contact your distributor or Adam Equipment. © Adam Equipment Company 2006...
  • Page 21: Rs-232 Interface

    9.0 RS-232 INTERFACE The CBW Series of scales are supplied with bi-directional RS-232 interface as standard. The CBW scale when connected to a printer or computer through the RS-232 interface, outputs the weight with the selected weighing unit. Specifications: RS-232 output of weighing data...
  • Page 22: Input Commands Format

    Sets the zero point for all subsequent weighing. The display shows zero. P<cr><lf> Prints the results to a PC or printer using the optional RS-232 interface. It also adds the value to the accumulation memory if the accumulation function is not set to automatic. © Adam Equipment Company 2006...
  • Page 23: Calibration

    • If an error message “FAIL H” or “FAIL L” is shown during calibration, re-check the calibration and repeat, if necessary. If the error cannot be corrected contact your dealer or Adam Equipment for advice. © Adam Equipment Company 2006...
  • Page 24: Error Codes

    Electronics may be damaged. To view the A/D count, press [Zero/Enter] and [%] at the same time while the scale is performing the initial check at power-on. Press [Zero/Enter] to return to normal weighing. © Adam Equipment Company 2006...
  • Page 25: Replacement Parts And Accessories

    12.0 REPLACEMENT PARTS AND ACCESSORIES If you need to order any spare parts and accessories, contact your supplier or Adam Equipment. A partial list of such items is as follows- • • Power Supply Module In use cover • •...
  • Page 26: Warranty Information

    The warranty will cease to operate if the equipment is not returned in the original packaging and with correct documentation for a claim to be processed. All claims are at the sole discretion of Adam Equipment. This warranty does not cover equipment where defects or poor...
  • Page 27 Shielded interconnect cables must be employed with this equipment to insure compliance with the pertinent RF emission limits governing this device. Changes or modifications not expressly approved by Adam Equipment could void the user's authority to operate the equipment. © Adam Equipment Company 2006...
  • Page 28 © Copyright by Adam Equipment Co. Ltd. All rights reserved. No part of this publication may be reprinted or translated in any form or by any means without the prior permission of Adam Equipment. Adam Equipment reserves the right to make changes to the technology, features, specifications and design of the equipment without notice.